Document the full feeder assembly, not a surface color
A silvery exposed conductor is not proof that every member in a feeder assembly is aluminum. Tinned copper, mixed metals, neutrals, shields and support elements can affect what the record means. Photograph the reel tag and jacket, then copy the manufacturer, part number, product designation, insulation and any stated metal or assembly description.
If a neutral or support member is visible but not documented, mark its construction unconfirmed. Do not translate a visual impression into a complete aluminum classification.
- Manufacturer and part number
- Product designation and insulation
- Conductor-metal source
- Neutral, shield or support description
Record size and remaining length without inference
Use AWG or kcmil printed on the tag or jacket; outside diameter is not a substitute. List each continuous length and show whether the footage is measured, documented or estimated. Full reels and partial reels should be distinct inventory lines so a partial balance is not represented as the original reel quantity.
When footage is unavailable, leave it unknown or estimated and explain the basis. A clear unknown is more useful than a precise-looking number with no source.
- AWG or kcmil
- Continuous footage
- Quantity basis
- Reel count and full or partial status
Separate condition from the material description
State whether the reel is uninstalled, removed or otherwise of unknown history. Photograph exposed ends, jacket abrasions, flange condition and known storage exposure. Those observations help describe the item without asserting electrical condition or suitability.
Keep weight information separate from material identity. If a reel weight is estimated, identify the estimate as such and retain the source rather than treating it as a measured handling fact.
- Unused, removed or unknown-history status
- End, jacket and flange condition
- Storage exposure
- Documented or estimated gross weight
Use project context without treating it as product evidence
The City of Tuscaloosa Engineering Division manages capital projects and infrastructure improvements and supports private development through design review, permitting and inspection.
A seller may use that context to explain why a feeder record needs a release decision, but it does not identify the conductor or prove that an assembly is available. The tag, jacket record and release authority remain the relevant evidence.
- Storage location
- Site access restrictions
- Available loading information
- Role authorized to release the lot
Worked feeder record and unconfirmed fields
Illustrative inventory example—not a purchased Tuscaloosa lot: AL-TCL-04 records an aluminum feeder designation copied from the tag and a documented neutral construction. It lists 275 ft continuous as estimated on a partial reel, with an exposed end noted and the reel flange intact.
If the tag does not prove every conductor’s metal, the record should say mixed or unconfirmed construction. The resolution is to retain the readable designation and the unknown field together, not to classify the whole assembly from appearance.
- Example: AL-TCL-04
- Length: 275 ft continuous, estimated; partial reel
- Condition: exposed end noted; flange intact
- Unknowns remain visible where documentation does not resolve them
