Start with the actual kV marking on each reel
Photograph and transcribe the marked kV, manufacturer, complete part number, and reel ID from the offered reel. A broad description such as power cable or a rating taken from a nearby reel does not settle the voltage class for this inventory line. Keep the visible marking and the inventory reference together.
List conductor metal, size, insulation, and shield or neutral construction only when the reel or a matching record supports them. This is not an installation guide or a condition certification; it is a traceability record for a buying inquiry.
- Marked kV transcribed exactly
- Manufacturer, part number, and reel ID
- Construction fields tied to supported evidence
Match each existing record by reel or batch identity
Existing production, batch, or other product records are useful only when their identifier and scope can be linked to the offered reel. Record the reel ID, batch ID if present, document date, and whether the match is confirmed, missing, or mismatched. Keep a document for another batch separate rather than treating it as evidence for the inventory line.
A mismatch is useful information. Stating it clearly allows the buyer to understand the record gap without assigning an unsupported kV or construction value. The industrial-cable page handles ordinary construction sorting; this page focuses specifically on the traceability of a marked voltage-rated reel.
- Reel ID and batch ID
- Document reference and date
- Match status stated as confirmed, missing, or mismatched
Record length and known condition history without overclaiming
For each reel or continuous piece, state the remaining footage and whether it is measured, documented, or estimated. Record known storage history, moisture exposure, end protection, and visible jacket condition as observed. Do not turn photos or existing records into a claim that the cable is fit for a particular use.
If an end cap is missing or a storage detail is unknown, make that limitation visible. The useful seller record is precise about what is known and what is not, rather than using a general medium-voltage label to imply a complete history.
- Continuous footage and quantity basis
- End protection and known storage history
- Visible condition described without a fitness claim
Illustrative traceability record
Illustrative example only—not a purchased or actual Queen Creek lot: MV-QC-11; 15 kV marking photographed; insulation level unknown; 720 feet documented; uninstalled reel; one end cap missing; no matching batch record. The example shows a usable buying record that preserves both the exact marking and the missing information.
Do not replace the unknown insulation field with a similar product’s data sheet. If a later record matches MV-QC-11, add the document reference and match status to the same line. Until then, the open gap stays visible.
Local utility context does not rate the offered cable
Invest The QC states that the Town of Queen Creek provides water and wastewater service for industrial sites and Salt River Project provides electric service for industrial sites.
That local service statement can provide limited background for a seller naming a documented project or site. It does not establish the marked kV, cable ownership, condition, or suitability of any reel. Those remain matters for the exact reel marking and its traceable records.