Why complete designation matters
A metal jacket or an 'armored' appearance is not a substitute for the exact product designation. For an accurate review we need the specific MC, MC-HL, TECK or manufacturer designation printed on the tag or jacket. That designation ties directly to conductor count, size, insulation system and marked voltage, and it is the primary field we use to assess the assembly description without dismantling.
Follow the supplied step 'Record the complete designation' exactly: capture exact designation, manufacturer, part number and any marked voltage. If a label is partially missing, photograph the remaining printing and record what is unreadable. Do not guess or replace the exact designation with a generic phrase.
The city’s Development Areas page publishes 2024 maps for City Center, Loop 303, North Surprise and Railplex. A seller may use one of those names only as a seller-provided storage or project group; the armor, label, and internal conductor record remain the basis for describing the cable.
- Evidence to supply: exact designation, manufacturer, part number, marked voltage
- Photograph tags and printed markings on the jacket and reel ends
- If designation is unreadable, record that explicitly and show close-up photos
Document the internal assembly without dismantling
The second required task is to describe the internal assembly using available documentation and markings. List conductor metal (for example copper or aluminum if explicitly marked), conductor count and size, grounding details and jacket construction when the information is present on labels or stamped markings.
Keep unknowns explicit. If you cannot verify conductor metal or count because the jacket is intact and there is no clear marking, state those fields as unknown. The correct decision is to record what is visible, not to infer conductor condition or reuse approval from an intact exterior.
- Evidence to supply: conductor metal, count/size, grounding, jacket
- Note whether conductor sizes are printed on the jacket or on a manufacturer tag
- When documentation conflicts, photograph both markings and note the discrepancy
Describe condition and visible damage without taking assemblies apart
Document armor and assembly condition by photographing accessible armor, both cable ends, any fittings and packaging, and by disclosing crushed sections, corrosion or other visible damage. Also include any service history the lot owner can provide.
Do not dismantle the assembly to inspect conductors. Use photographs to show damaged areas and record where armor is intact. State whether ends expose conductors or remain sealed; this influences whether continuous length and reel count are verifiable without internal inspection.
- Evidence to supply: armor condition, cable ends, fittings, service history, visible damage
- Photograph each continuous length from both ends and the middle where possible
- List reported service history such as removed-from-service dates or project notes if available
Separate quantity and weight and report continuous lengths
List each continuous length and record reel count and gross assembly or reel weight separately from any conductor-only weight. If assemblies are removed and bundled, state 'removed' and disclose how many continuous runs and estimated lengths remain intact.
If the assembly removed from service has had conductor or armor partially removed, do not combine that partial status with intact assembly counts. Make the condition status for each line item explicit: unused, removed, cut, bundled, or otherwise altered.
- Evidence to supply: continuous length, reel count, gross assembly/reel weight, condition status
- If you cannot provide exact weight, give gross estimates and note the method used (scale, reel tag, etc.)
- Distinguish unused (never installed) from removed (taken out of service) material
How to handle unknown or incomplete inventory information
If you do not have complete markings or cannot confirm internal conductor details, be explicit: mark fields as 'unknown' and show close-up photos of the readable portions. Use the four documentation steps to reduce unknowns where possible: capture designation, describe assembly markings, photograph condition, and list lengths and weight estimates.
Providing incomplete information is acceptable so long as unknowns are clearly called out. We will evaluate what can be confirmed from the visible evidence rather than presuming conductor condition or electrical suitability from the armor exterior.
- Do not infer conductor size or metal from armor alone; state 'unknown' when uncertain
- Where partial markings exist, photograph and transcribe exactly what is readable
- Include an honest statement about whether each length is continuous or cut into multiple pieces