Capture the designation printed on the cable
Begin with the jacket legend. Copy TC, TC-ER, PLTC, or the complete readable designation as it appears, together with the manufacturer, part number, and marked voltage when available. Take photos that show enough of the printing to connect the words to the reel or cut length.
If printing is worn or missing, use “designation unknown.” Do not call a cable Type TC simply because it came from a tray. A storage route, a project label, or a cable’s outside appearance does not establish its factory designation.
- Exact readable jacket designation
- Manufacturer and part number when available
- Marked voltage and data-sheet reference when matched
- Photo reference tied to the reel or piece ID
Separate close variants before combining footage
Create separate lines when conductor count, pair count, gauge, overall shielding, individual shielding, or jacket construction differs. Two reels can share a broad designation while still differing in ways a seller should keep visible. Do not turn several similar-looking pieces into one aggregate footage line.
The common mistake is to put every cable taken from a tray under one Type TC description. The workable correction is to preserve actual markings, list each construction separately, and leave the designation unknown where neither the cable nor a matching record supports it.
- Conductor count or pair count
- Gauge for the recorded construction
- Overall or individual shield description
- Jacket variation and distinct line ID
Treat a reel and a cut length as separate pieces
Give each reel or cut length its own ID and continuous footage. Label footage measured, documented, estimated, or unknown. Include fitted-end status and condition in the same row, because a partial reel and a cut length do not represent the same inventory situation even when their printing matches.
Where the seller has only a partial record, retain the visible conductor count, gauge, shielding observations, and photographs. A candid incomplete row is more useful than a total that combines unknown and documented pieces.
- Reel or cut-length ID
- Continuous footage with quantity basis
- Fitted ends or terminations described
- Visible condition and known storage notes
Keep public utility context in proper scope
Fort Smith Water Resources manages water and wastewater treatment plants, lift stations, storage tanks, transmission facilities and watershed operations. That fact may be useful context for a seller organizing utility-related control or tray cable, but it does not identify a municipal lot, a cable source, or release authority for any inquiry.
For the real offered material, document whether it is uninstalled stock, a project overrun, or previously removed cable. Then add the actual owner, release authority, storage location, and access information. Those seller records, not public infrastructure context, define what can be discussed.
- Uninstalled, overrun, or removed condition history
- Actual owner and release authority
- Storage location and loading-access notes
- Unknown owner or release field left explicit
Make the unknown designation reviewable
Fictional example—not a purchased lot: CT-FS-03 has a photographed TC-ER marking, 12 conductors at 16 AWG, shielding unknown, 240 ft continuous measured, and removed-cable status with fitted ends present. It shows a line where known construction and one unresolved field remain visible together.
If the legend cannot be read, retain the same field structure but state designation unknown and attach the best evidence. Email the line-item inventory and photos to saleselectricalbuyers@gmail.com so Industrial Wire Buyer can review the disclosed material record without treating an assumption as a specification.
- Example line ID: CT-FS-03
- Designation: TC-ER marking photographed
- Construction: 12 conductors, 16 AWG; shielding unknown
- Quantity: 240 ft continuous, measured; fitted ends present