Read the designation on the offered cable
Begin with the actual jacket legend and reel label. Copy TC, TC-ER, PLTC or another designation as printed, together with the manufacturer, part number and marked voltage. A location description such as control room cable or material taken from a tray may be background, but it cannot replace the product record for the reel in front of you.
The City describes capital projects that include street, sidewalk and alley rehabilitation, traffic-signal upgrades, water, recycled-water, sewer and stormwater improvements, public lighting and park work. Those categories can be part of a seller’s stated source context, but they do not establish a control-cable type, a reel quantity or demand. Product evidence remains the relevant seller record.
- Printed TC, TC-ER, PLTC or other exact designation
- Manufacturer, part number and marked voltage
- Photo reference for label and jacket printing
- Source context kept separate from specification
Split differences that a quick view misses
Create separate lines for each conductor count, pair count, gauge, shield arrangement and jacket difference. Do not merge reels because their colors, reel size or storage location appear alike. For multi-pair products, say whether the count is conductors or pairs; treating those units as interchangeable can distort the actual assembly.
Use one line per continuous reel length or truly identical group, retaining individual footage and fitted-end differences. Where shielding or pair count cannot be read, state unknown and include the available photograph. A smaller accurate description is preferable to a larger line built from an assumption.
- Conductor count and pair count as separate fields
- Gauge and shield arrangement
- Jacket designation and visible fitted ends
- Per-reel continuous footage and quantity basis
Keep condition history tied to the line
State whether the cable is uninstalled stock, a project overrun or a previously used length, and describe the known storage history and visible jacket condition. A designation identifies a product; it does not establish the present condition of the reel. Do not use a clean photograph as proof of history or suitability.
Match photographs and any existing documents to the same reference used for length and specification. Include the storage location and release authority for the seller-held material. If a reel is waiting on approval, mark that status instead of treating it as immediately available.
- Condition and known history
- Visible jacket or end observations
- Matching document and photo reference
- Storage location, release contact and pending status
Illustrative control-cable split
Illustrative inventory example—not a purchased lot: CT-DWY-05 shows TC-ER marking, 12 conductors, 16 AWG, 240 feet measured and shielding unknown. A second reel with a different pair count or shield record would receive a separate line even if it came from the same storage rack. The example is fictional and does not classify all tray-origin cable as TC.
Send the designation photos and the separate line items to saleselectricalbuyers@gmail.com. Retaining a visible unknown is useful because it directs the next documentation question without changing the product description.