Capture the complete armored-cable designation
Photograph the factory tag, sheath printing, and any attached labels for each reel or bundle. Record Type MC, MC-HL, TECK, or the actual designation shown, along with manufacturer, part number, and marked voltage. Terms such as armored cable are a starting label, not a substitute for the construction record.
Where printing is rubbed or a tag is absent, say so. Preserve a clear image of what remains and keep the reference separate from fully identified stock. Do not assign a product family only because the visible exterior appears metallic.
- Product designation, manufacturer, and part number
- Marked voltage where visible
- Reference matched to tag and sheath photos
Describe the internal assembly from evidence
Use the available product record, label, or matching packing document to list conductor metal, count and size, grounding arrangement, and jacket details. Make clear which facts are stated by a source record and which fields are unknown. The goal is a traceable assembly description without cutting or dismantling the cable for this inventory page.
A standard designation may help locate a record, but it cannot prove the internal fields of an unlabeled reel. Keep an unmatched packing list or generic specification separate until it can be connected to the actual reference.
- Conductor metal and count or size
- Grounding arrangement and jacket details
- Matching document reference or explicit unknown status
Separate visual armor condition from material identity
Record full reels, partial reels, and removed cut lengths on different lines. Give each a continuous length, reel count, fittings, service history, and visible armor condition such as crushing, corrosion, exposed ends, or compromised fittings. State the length basis when any figure is estimated.
An intact exterior is a visual observation, not evidence of internal conductor condition or cable-only metal weight. If a weight is available, label it as gross assembly, gross reel, or another stated basis rather than using it as a conductor-content claim.
- Continuous length and measured or estimated basis
- Armor condition and fitted ends
- Weight basis distinct from conductor content
Limit Fairfield context to its real purpose
The City of Fairfield says spaces are available in seven Industrial/Business Parks and identifies food and beverage manufacturing among Fairfield’s industry clusters.
It provides warehouse and facility context for this seller task only. It does not establish an armored-cable lot, an installation, local demand, or a relationship between the City and Industrial Wire Buyer.
- City context does not replace assembly documentation
Correct the exterior-only inventory record
The specific mistake is treating intact armor as proof of internal conductor condition or conductor weight. Correct it with an exact assembly record, a stated gross weight basis where relevant, and an honest visible-condition note. This avoids turning a general exterior observation into a technical claim about the offered cable.
A fictional example is AR-FW-01: Type MC tag, 3 conductors plus ground, size on label; 190 ft continuous, estimated; removed with two crushed sections disclosed; location and loading resources unknown. It is an illustrative inventory record, not an offered or purchased lot.
- Do not infer conductor material from armor
- Keep damaged and fully documented reels distinct