Capture the rating from the actual reel
Photograph and transcribe the marked kV, manufacturer, part number, and reel ID from the material being offered. If the label is partly obscured, show the readable portion and write the missing characters as unknown. A project category, equipment label, or site description does not establish the cable rating.
Keep conductor metal and size, insulation, and shield or neutral construction as separate fields. Include a data sheet only when its part number or construction can be matched to the specific reel.
- Marked kV, manufacturer, part number, and reel ID.
- Conductor metal and size.
- Insulation and shield or neutral construction.
- Matching data sheet, if available.
Match batch and record scope before using a document
Record a batch or lot ID, record date, and the stated scope of any production, storage, or existing test record. The record should identify the offered reel or a batch that demonstrably includes it. A similar reel’s document is not a reel match.
The common error is filling a missing rating or history with material that merely looks alike. Instead, leave the unmatched field explicit and show the source of the record. Documentation can add context, but it is not a statement of electrical fitness or a purchasing outcome.
- Batch or lot ID.
- Record date and stated scope.
- Explicit reel or batch match.
- Unmatched records labeled as unmatched.
Describe quantity and visible handling facts
Enter continuous footage with a measured, documented, estimated, or unknown basis. Note accessible end protection, known storage history, reel dimensions, and weight basis. Photographs describe what is visible; they do not establish the internal condition of a cable reel.
Keep one reel per line unless every material and quantity field is genuinely the same. A reel that lacks an end cap or record should retain that distinction rather than inheriting it from the best-documented reel in the group.
- Continuous footage and its basis.
- End protection and known storage history.
- Dimensions and stated weight basis.
- One traceable line for each nonmatching reel.
Keep project context in its proper scope
A City solicitation lists roads, bridges, drainage facilities, utilities, facilities, airport, parks, trails, signals and street lighting among capital-improvement project types and studies. This can be background for a seller’s project record, but it does not supply a kV value, cable construction, or inventory availability.
For a medium-voltage review, the photographed marking and matched reel or batch record remain the decision evidence. Do not substitute the project type for those fields.
- Project name or type is background only.
- Use reel-specific markings and records for the material record.
Worked traceability record and unknowns
Illustrative inventory example—not a purchased lot: MV-LIV-01; 15 kV marking photographed; insulation level unknown; 720 ft documented; uninstalled reel; one missing end cap; no matching test record. The example shows that a clear rating can coexist with an incomplete construction or records file.
If an identifier is missing, preserve the visible material and name the gap. Provide the reel record and images through the quote form or saleselectricalbuyers@gmail.com rather than completing the file with a neighbor reel’s information.
- Example is fictional and is not a purchased lot.
- Missing insulation level and record match remain explicit.
