Start with written metal evidence, not a visual guess
An exposed silvery conductor is not enough to establish the metal or the complete feeder construction. Visual appearance can be misleading, and a single visible element does not describe every conductor, neutral, shield, or support member in an assembly. Use the readable reel tag, jacket legend, manufacturer part number, or matching product record as the source for each stated field.
Photograph and transcribe the designation exactly as it appears. When the tag is absent, damaged, or conflicts with a record, do not choose the more convenient description. Mark the metal, size, or assembly field unconfirmed and preserve the conflicting references for a lot-specific review.
- Record the manufacturer designation and complete part number verbatim.
- Capture a printed metal statement when present and mark its absence when it is not.
- Keep insulation designation and marked voltage as separate fields.
Describe the full feeder assembly
A useful feeder record separates conductor size from cable outside diameter and separates conductor count from neutral, shield, or support descriptions. Copy AWG or kcmil only from the tag, jacket, or a product document that matches the reel. Do not estimate size from diameter or combine an undocumented support member into an assumed aluminum total.
If a data sheet is available, write the part number and page or file reference that actually corresponds to the offered item. If no matching document is available, the unknown is still valuable information; it tells the buyer which element needs confirmation rather than creating an unsupported specification.
- List conductor count and documented neutral, shield, or support-member descriptions.
- Keep a matching data-sheet reference with the exact reel reference.
- Do not infer any assembly field from jacket color, metal color, or a nearby reel.
State the balance, condition, and site facts separately
List each continuous remaining length by reel. A partial balance can be estimated, but the record should say it is estimated and describe the basis. Keep uninstalled stock, removed cable, and unidentified material distinct. Note visible end condition and reel condition without treating an exterior observation as a performance conclusion.
The same line should identify its weight basis as gross, net, estimated, or unknown; then list storage location, release authority, and available loading or access limits. These are practical handoff facts, not assumptions about the transport arrangement or an offer.
- Use a separate reel reference for every continuous length.
- Label estimated footage and state its documented or observed basis.
- Record exposed ends, storage location, release authority, and access limits honestly.
Use local project context narrowly
The City of Merced's Yosemite Avenue Roadway Reconstruction Project runs from G Street to Parsons Avenue and includes sewer, traffic-signal, roadway and accessibility work.
A contractor or public-works record associated with that project may assist in locating files. It does not identify the offered feeder, establish aluminum content, prove footage, or authorize release. The feeder record remains dependent on its own tag, jacket printing, matching documents, and current inventory details.
- Match any project document to the exact reel reference before relying on it.
- Treat absent metal, size, or assembly evidence as unconfirmed.
- Provide the actual storage and release facts for the offered cable, not a project-name substitute.
Prepare a fictional feeder line with visible unknowns
A clearly fictional line can show the required discipline: reference AL-MER-02; aluminum feeder designation from reel tag; neutral construction documented; one partial reel with 275 ft continuous, estimated; uninstalled with an exposed end noted; weight unknown and not inferred from outside diameter; warehouse authorization documented. It is a format example, not a purchased lot.
For a real inquiry, send the per-reel list and legible images through the quote form, then email inventory sheets or photos to saleselectricalbuyers@gmail.com. Keep incomplete fields explicit so any follow-up concerns the actual missing evidence rather than a presumed aluminum assembly.
- Example only: do not describe the fictional line as a Merced transaction.
- Retain the tag image, jacket image, and any matching record with the same reference.
- Use “unconfirmed” or “unknown” where the evidence does not establish a feeder detail.