Sort variants before creating the lot total
Create a separate row whenever printed designation, conductor count, pair count, gauge, shield arrangement, jacket, or fitted ends differ. Similar reel sizes and jacket colors are not enough to group cable. Put the reel ID first, then record the exact legend and construction fields beside it. This turns a mixed control-cable stack into a record a buyer can compare line by line.
For a reel with an unreadable legend, create an unknown-designation row. Do not call it Type TC because it was found in a tray, and do not copy the specification from the next reel. The unknown is actionable when it is linked to clear photos and a measured or estimated continuous length.
- Split different pair counts and gauges even when the jackets look alike.
- Keep unknown-designation cable out of a confirmed Type TC or TC-ER group.
- Record fitted ends on the same row as the cable construction.
Capture the complete printed designation
Photograph a legible section of jacket text, the reel tag, and the overall reel. Transcribe designation terms such as TC, TC-ER, PLTC, or another printed description exactly rather than abbreviating them into a generic category. Also capture manufacturer, part number, and marked voltage if shown. Use the same reel ID in the photo filenames and the worksheet.
A project document can be kept as background, but the physical legend and matching product record are stronger item-level evidence. If a data sheet is available, identify which reel it covers. A generic document for similar cable should be marked as unmatched rather than attached as proof for the offered reel.
- Use overlapping photos when the legend wraps around the jacket.
- Transcribe only visible characters; write unknown for unreadable text.
- Keep the data-sheet filename with the exact reel reference.
Report continuous length and condition honestly
Record each continuous piece rather than adding separate cut lengths into one apparent run. State whether footage is measured, tag-supported, or estimated. Keep unissued stock, project overrun, and previously in-service cable on separate lines because their histories are different even when the specification matches.
Add visible jacket condition, storage exposure, and fitted-end notes without treating photographs as a performance finding. If shielding, footage, or history cannot be verified, leave it unknown. The point is a precise inventory record, not an assumption that a readable designation answers every condition question.
- Mark each quantity as measured, documented, or estimated.
- List partial reels and separate cut pieces independently.
- State unknown shield or condition-history fields explicitly.
Keep traffic-project context in its proper place
The city lists traffic-signal synchronization work on major corridors including Santa Margarita Parkway, Trabuco Road, Marguerite Parkway, Olympiad/Felipe and Crown Valley, with La Paz Road and Cabot Road noted as upcoming projects. A seller may use a truthful project reference to explain why an inventory record exists. That city context does not identify a cable as control or tray cable, establish a specification, or show that any material is for sale.
If a project name appears on a tag, put it in an origin or notes field. The specification fields remain the physical jacket designation, conductor or pair count, shielding, and marked rating for that exact reel.
- Use project names as origin notes, not as product designations.
- Do not infer Type TC from a tray or traffic application.
- Keep release authority and storage facts with the offered reel record.
Worked control-cable record
Illustrative inventory example—not a purchased lot: Reel MV-CT-11 is a fictional cable record with “TC-ER marking photographed,” “12 conductors, 16 AWG; shielding unknown,” and “240 feet measured continuous.” Its condition note says previously in-service cable with fitted ends present. The fields demonstrate how a known designation can coexist with an unknown shielding detail.
If the legend cannot be read, change the designation to unknown, keep the reel separate, and attach the photograph that shows the limitation. Do not repair an incomplete row by applying the known attributes of MV-CT-11 to a different reel.
- Example reel ID: MV-CT-11.
- Example measured length: 240 feet continuous.
- Example unknown: shielding detail.