Capture the marked rating from the actual reel
Make the reel ID the center of the record. Photograph and transcribe the marked kV, manufacturer, part number, and readable jacket text from that reel. Record the continuous footage with its basis and show enough of the reel that the marking and inventory reference can be connected. A project title or a nearby reel may be useful background, but neither supplies the offered reel’s rating.
If the kV marking is rubbed, incomplete, or absent, mark it unknown and preserve a close photograph of the affected area. Do not fill the gap with a rating from a similar reel. The point of the record is traceability, not a plausible-looking description.
- Use one reel ID in the inventory, photos, and supporting records.
- Transcribe marked kV, manufacturer, part number, and jacket text.
- State continuous footage as measured, documented, or estimated.
- Leave an unreadable or absent marking explicitly unknown.
Match existing records by reel or batch reference
Keep insulation detail, shield or neutral description, and any existing production or inspection record with the reel only when the reference truly matches. Record the document date and scope, then note whether the document names the reel, a batch, or a production range. A document with an unmatched reference can be retained as background but must not be represented as support for the offered reel.
This is the central distinction for a medium-voltage submission. A similar cable construction is not enough. The seller should show the reference relationship or say that it is unknown, so the review can distinguish a documented reel from one with incomplete records.
- Capture the document’s reel, batch, or lot reference.
- Keep record date and scope with the specific inventory line.
- Identify documents from a different batch as non-matching.
- Leave insulation or shield detail unknown when unmatched.
Describe physical condition without making a fitness claim
For each reel, record whether it is uninstalled, partly used, or has a prior-service history; then note visible jacket damage, end protection, storage history, and the accessible cable ends. Photographs can document observable condition, but they do not establish electrical performance or a future use. Keep the description to what is present and known.
A missing end cap, exposed cable end, damaged flange, or moisture observation belongs beside the same reel ID as the kV marking. That pairing helps prevent a clean photograph of one reel from becoming a stand-in for another reel with a different condition history.
- Photograph accessible cable ends, jacket condition, and reel flanges.
- State end-protection status and observed storage history.
- Separate uninstalled reels from partial or prior-service material.
- Describe visible damage without assigning performance conclusions.
Prepare release and handling information as evidence
Add approximate reel dimensions, an identified gross, net, or estimated weight basis, the release authority, site access restrictions, and observed loading resources. These fields describe the seller’s material and location; they do not promise a collection method or schedule. Keeping them on the same record allows practical discussion after the cable itself is understood.
Perris's official planning page lists local industrial and logistics proposals including First Industrial Logistics at Harley Knox Boulevard, Ethanac Logistics Center, Perris Airport Logistics Center, Ellis Logistics Center and Nance Business Park. For a seller, that local context can be used to organize internal industrial-project records, but it does not show that a listed proposal contains medium-voltage cable or that any inventory is available.
- State flange diameter, width, or other known reel dimensions.
- Name whether weight is gross, net, or estimated.
- Identify the release authority and site access constraint.
- Record observed loading resources as site facts.
Keep record gaps visible in the worked line
The likely reporting error is using a matching-looking reel or a record from another batch to fill a missing rating or construction field. Instead, keep the offered reel’s gap visible and identify the non-matching document as such. This approach supports an honest review without offering technical conclusions or pre-deciding the commercial outcome.
Illustrative inventory example—not a purchased lot: MV-PER-01 has a 15 kV marking photographed and insulation level unknown; it has 720 ft documented and is an uninstalled reel with one end cap absent and no matching record provided. The example shows that a useful line can contain known physical facts and clearly labeled unknowns.
- Do not borrow kV or construction details from another reel.
- Keep non-matching records outside the offered reel’s support.
- Flag missing end protection and missing documentation.
- Preserve the reel-specific identifier in every file name.