Capture the actual cable designation
Photograph the reel label and readable jacket legend, then transcribe the complete printed designation, manufacturer, part number, and marked voltage. A reel located in a tray is not automatically Type TC, and a cable near a control system is not automatically a control product. Keep the printed wording intact, including any portion that cannot be read.
Roseville Electric’s official page provides commercial rebates, new or upgraded electric service information, current projects and an Electric Department project category. That local fact is limited background for a seller’s records; it does not identify a control cable, establish a project inventory, or imply that the utility is a customer.
- Use the actual TC, TC-ER, PLTC, or other readable designation when present.
- Create an unknown-designation line when the legend does not support a label.
Split reels by construction fields
Use separate lines when conductor count, pair count, gauge, shielding, or jacket differs. A visually similar outer jacket does not justify grouping. The line should identify whether shielding is stated, unknown, or absent according to the readable marking or matching product record.
This grouping decision is the core of the page. It prevents a mixed group of multi-conductor reels from being described as one product simply because the reels came from the same tray or project area.
- Compare conductor count, pair count, gauge, shielding, and jacket before grouping.
- Keep unknown shielding separate from a documented shielding configuration.
Preserve continuous length and ends
For every reel or cut length, state the continuous footage and whether it is measured, documented, or estimated. Note fitted ends as a field, not as an afterthought, because they can differ across lengths that share a general designation.
If several items are coiled together, do not convert their total length into a single run. Give each known continuous piece a reference and explain any estimation method. An honest unknown is preferable to a precise-looking total without support.
- Record one reference per reel or continuous piece.
- State fitted ends and quantity basis beside the length.
Match records and surface unknowns
Link a data sheet or existing record only to the reel reference it actually matches. If an inspection note applies to another cable, retain it separately. For an unreadable legend, list exactly what is missing—such as pair count unreadable or shielding unknown—along with photo references.
The resolution is not to infer a designation from prior location. It is to preserve the uncertain line separately, document the remaining evidence, and keep an identified group from absorbing a different or unknown construction.
- Use a photo reference and record-match status for each uncertain line.
- Do not use tray location as an identity field.
Worked control-cable record
Illustrative inventory example—not a purchased lot: CT-RV-05, TC-ER marking transcribed from the jacket, 12 conductors at 16 AWG, shielding unknown, 240 feet continuous and measured, previously used cable with fitted ends. The example is fictional and is not a description of a Roseville purchase.
This page differs from the industrial-cable page because its seller decision is whether multi-conductor reels can be grouped by pair count and shielding. It differs from the copper page because the key quantity question is construction-matched continuous length, not a conductor-weight basis.
- Illustrative fields: designation, conductor count, pair count, gauge, shielding, reel reference, length, fitted ends.
- Keep a fictional example separate from actual inventory evidence.