What we require on arrival
Every offered reel or continuous length must be documented to the construction we will evaluate. Start at the reel or coil and transcribe the full manufacturer part number and any jacket printing exactly as it appears. Record conductor count and conductor size (for example "4 conductors, 6 AWG"), the conductor metal, any voltage marking, and whether a shield or armor is present.
If a matching product sheet, factory data sheet, or project drawing exists for that specific reel, note the document title, date and how it links to the reel ID. If a construction detail cannot be confirmed on the reel or by a linked document, mark that field unknown rather than assuming the value from an adjacent item.
- Manufacturer part number and jacket printing (transcribe verbatim)
- Conductor count/size and conductor metal
- Marked voltage and shield/armor status
- Reel ID and any matching document reference
Separate by history — unused stock vs removed runs
Split lots by how the cable was acquired and used. Keep uninstalled maintenance or project stock physically and on the listing separate from removed runs recovered from plant equipment or conduit. For each line, state whether it is unused or removed, describe fitted ends or terminations, and document continuous length when possible.
Be explicit about fitted ends: note if there are lugs, crimped ferrules, cut ends or identifiable termination hardware. For removed runs, include any known service history such as the process area name and the date it was removed, but do not use the process area name as the cable construction specification.
- Mark unused/removed status for every reel or continuous length
- Document fitted ends and continuous length
- Provide any available service history without substituting it for construction details
Tie records to the item and mark unresolved fields
Where available, attach or reference data sheets, submittals or prior inspection records to the specific reel ID. Record the document name and date under the matching document evidence field. When details differ across reels, keep the data with the reel and do not merge attributes from nearby reels.
If you cannot verify a field, list it under unresolved fields. For example, if shielding is not visible on a cut sample and no product sheet is available, set "shield/armor: unknown." This preserves honesty in the lot description and avoids the mistake of using a nearby reel's data.
- Match each reel to a reel ID and any matching document with document date
- List unresolved fields explicitly when verification is not possible
- Do not infer construction from adjacent reels or plant names
Record site release and access with the cable line
Salinas says its Industrial Wastewater Sewer serves 24 industrial users via permitted connections in the southern end of the city and conveys discharges to a treatment plant along the Salinas River. That is process-area context only, not evidence that any operator has cable available; the offered line still needs its own jacket markings, history, controller, and access details.
State the storage location and the role that can authorize release, then list gate, clearance, or loading limitations as facts. Those site details describe the offered lot; they do not establish that removal, transport, or acceptance has been agreed.
- List the storage location and access limits for the offered line.
- Identify the role that controls release without publishing private contact details.
- Describe available loading resources as site facts, not as a transport arrangement.
How we evaluate ambiguous or partial records
When jacket printing or a traceable product sheet is present, we will use those as primary evidence of construction. If only a plant-equipment name or process area is provided, it is insufficient to identify conductor size, shield status or jacket compound. In that case we will place unresolved fields on the item until physical markings or a matching document are provided.
If continuous length is not documented, note whether the reel is full, partial or cut-down and provide the visible reel ID. For lots where multiple partial reels exist, indicate whether lengths are tied together by a common reel ID or historic record; if not, treat each physical piece as a separate line.
- Prefer jacket printing and product sheets over facility area names
- Mark unknowns and separate partial reels into distinct lines when necessary
- Describe fitted ends and any visible wear that affects traceability
Illustrative record (how to present one line)
Provide one representative illustrative record for each line you list. Use the following example fields and follow the same level of detail. This is illustrative only and not an offer acceptance.
Include reel ID, exact part number or jacket text, conductor count and size, continuous length, condition (unused or removed), shield/armor status (or unknown), matching document reference if available, and release authority.
- Reference: IC-SAL-02
- Product: part number recorded; 4 conductors, 6 AWG
- Quantity: 420 ft documented continuous
- Condition: uninstalled maintenance stock; shield status unknown
- Release: warehouse access and approving controller to be confirmed