Transcribe the jacket designation before grouping reels
Start with the actual printed designation: TC, TC-ER, PLTC, or whatever wording the jacket or record shows. Retain the manufacturer, part number, and marked voltage when they are available. A reel’s location in a tray or its association with a project is not a substitute for that product record.
If the text is worn or incomplete, photograph the area, assign a reel ID, and write “marking unreadable” for the missing characters. Do not fill the designation from a nearby reel. That small discipline prevents an apparent category from becoming an unsupported material specification.
- Printed designation copied exactly
- Manufacturer, part number, and marked voltage
- Unreadable text photographed and labeled unknown
Split construction variants at the field that differs
Create separate lines for conductor count, pair count, gauge, shielding, and jacket differences. For example, the same gauge with different overall or individual shielding is not automatically one specification. Retain each difference even when the reels look alike or came from the same storage area.
Use the same approach for genuinely matching reels: list the criteria that match, keep each reel’s own footage, and leave a differing construction line separate. This page is not a general plant-cable classification; its seller task is deciding which multi-conductor details make a line actually comparable.
- Conductor count, pair count, and gauge
- Overall or individual shielding
- Jacket details and product designation as group criteria
Tie length, fitted ends, and history to each reel
Record a reel ID, continuous footage, and quantity basis for every reel or defined continuous length. A fitted end, a splice, or a different footage basis belongs on the line where it occurs. That lets a reviewer distinguish one long documented reel from several shorter pieces with a similar jacket.
Also state whether the line is uninstalled stock, project overrun, or has a removed-service history. Describe visible jacket damage and storage exposure without turning those observations into a technical condition claim. Where the history or a field is unknown, preserve the unknown rather than grouping it with more fully documented stock.
- Reel ID, continuous footage, quantity basis, and photo reference
- Fitted ends recorded per item
- Condition or history and visible damage stated separately
Use a fictional control-cable line to show the decision
Illustrative only—not a purchased Vallejo lot: CT-VJ-05 has a TC-ER marking, 12 conductors of 16 AWG, and 240 feet of measured continuous length. Its record says “removed cable; fitted ends present; shielding unknown.” The shielding gap remains visible even though the designation and conductor count are recorded.
The common mistake is labeling all cable that came from a tray as Type TC and combining it into one total. Correct it by using the jacket or matching record to establish the designation, then retaining separate lines for conductor or pair count, shielding, and reel balance differences.
- Reference: CT-VJ-05
- Designation: TC-ER; 12 conductors, 16 AWG
- Condition: removed history; fitted ends present; shielding unknown
Place the local fact beside, not inside, the material claim
Vallejo says its Economic Development Department provides new-business recruitment, technical assistance for existing businesses, business retention, site-selection assistance, management of City-owned property and Mare Island conversion. It does not establish a control-cable lot, a customer, an affiliation, or demand for any particular construction.
For this seller task, Vallejo context does not replace the printed designation. Keep the location, release authority, and storage facts in the inventory alongside the reel records, and email photo files using those same references to saleselectricalbuyers@gmail.com.
- Local context is not proof of cable type or availability
- Seller-supplied location and release facts remain separate
- Photo filenames should match reel IDs