Treat tray location and product type as different fields
The City’s public-improvement program covers underground infrastructure, City facilities, roads and sidewalks, and traffic systems; it highlights an 86th Parkway sewer-line replacement project. These public categories offer limited local context for records involving control or facility systems, but they do not establish that a reel is Type TC or tied to a City project.
Copy the actual jacket legend. It may include Type TC, TC-ER, PLTC, another designation, or no readable designation at all. Where the legend is incomplete, photograph it and list the uncertainty. Cable being stored in, taken from, or intended for a tray does not itself establish the product type.
- Printed designation
- Manufacturer and part number
- Marked voltage
- Complete jacket-legend photo
Split the fields that make similar reels different
Create separate lines for changes in conductor count, pair count, gauge, shielding, jacket, or fitted ends. Keep an overall shield and individual-pair shielding distinct when an existing record identifies them. Do not use a broad control-cable label to conceal an unreadable or mismatched construction.
The predictable error is classifying all material from a tray as Type TC. The repair is to rely on the reel tag, jacket printing, and matching product record. An unknown designation stays unknown, even if a neighboring reel has a familiar marking.
- Conductor or pair count
- Gauge
- Overall or pair shield field
- Jacket designation
Make quantity and history legible
List continuous footage for each reel and identify it as measured, documented, or estimated. State whether cable is uninstalled stock or has been removed from prior service, then describe fitted ends and visible jacket condition. Do not represent a photograph as proof of internal condition or an approval for future use.
An illustrative fictional record, CT-ARV-05, can show a TC-ER marking, 12 conductors at 16 AWG, 240 feet measured, fitted ends present, and shielding unknown. It models precise fields and an honest gap; it is not a seller inventory or a previously purchased lot.
- Reel ID
- Continuous footage and basis
- Uninstalled or removed status
- Fitted-end and condition photos
Keep documents matched to the reel
Use a stable reel reference in the inventory, photo filenames, and any data sheet or inspection record. If a document applies to another construction or reel, do not attach it as support for this one. This protects the specific Type TC or control-cable distinction that makes the page useful.
Add the storage location and access limitations after the technical line fields are complete. Those practical notes let an actual lot be discussed without turning a cable description into a promise about movement, acceptance, or transaction terms.
- Stable reel reference
- Matching product record
- Storage location
- Access limitation