Step 1 — Transcribe the product marking
Begin by recording the printed legend visible on the jacket for each continuous length or reel. Transcribe the exact printed designation (TC, TC-ER, PLTC, or any manufacturer text), manufacturer and part number if present, voltage rating, conductor count, pair count, and gauge. Capture a clear jacket photo and save it with a descriptive photo filename that links to the record.
If the jacket shows a full legend, record it verbatim. The supplied step from the brief emphasizes exact transcription: printed designation, manufacturer/part number, voltage, conductor count, pair count, and gauge are required evidence fields.
- Evidence to capture: printed designation; manufacturer/part number; voltage; conductor count; pair count; gauge
- Attach a jacket photo and link the filename to the reel or cut-length record
Step 2 — Keep variants on separate lines
Do not combine reels or cut lengths that differ in shielding, jacket type, fitted ends, conductor/pair count, gauge, or specification group. Create a distinct inventory line for each materially different construction even when outer jackets look similar.
Record the shielding status explicitly (shielded, unshielded, drain presence unknown) and include reel ID or internal line ID. The brief requires keeping shielding, jacket, fitted ends, specification group, and reel ID as evidence fields to avoid the common mistake of aggregation.
- Separate lines by: shielding, jacket, fitted ends, specification group, reel ID
- If two reels share all required evidence fields exactly, they may be grouped; otherwise keep them distinct
Step 3 — Tie length to each reel
Record continuous footage or meterage linked to each reel or cut-length and label the quantity basis (measured, estimated, or documented). Keep removed cable, uninstalled stock, and cut-lengths distinct in condition/history. For each line include continuous length, quantity basis, condition/history, and cut-length status as required evidence.
When you measure, record who measured it and how (tape, reel counter), and attach the measurement note as part of the record. If the cable was removed and has fitted ends, note that in the condition field so reviewers know whether ends are present.
- Evidence to capture: continuous length; quantity basis; condition/history; cut-length status
- Label measured vs estimated quantities clearly on the line
Step 4 — Resolve incomplete legends honestly
When jacket legend text is incomplete or rubbed off, use a matching manufacturer data sheet only if it clearly matches the reel’s markings and construction. Preserve uncertainty where you cannot confirm the designation rather than borrowing information from another reel.
Capture a jacket photo and a reference to any data-sheet used. Required evidence fields include jacket photo, data-sheet reference, unknown field notation, and the photo filename. If uncertainty remains, mark the designation or shielding as unknown in the line record.
- Evidence to capture: jacket photo; data-sheet reference; unknown field; photo filename
- Do not assume TC or TC-ER when legend is missing—mark unknown and note the reason
Common mistake and the correct resolution
A frequent error is to mark every cable found in a tray as Type TC and combine all conductors and shielding variants into a single product line. That practice hides material differences and slows validation.
The brief’s resolution is explicit: use the actual markings and matched records, split materially different constructions into separate lines, and retain unknown designation or shielding as unknown rather than guessing. Follow the four steps above so each inventory line stands on its own documented evidence.
- Mistake: combining multi-count and shielding variants into one line labeled Type TC
- Resolution: split by construction, preserve unknowns, and require the listed evidence fields
Illustrative record example
Record the following illustrative line exactly as an example of format and fields to include (this is not a purchased lot): ILLUSTRATIVE ONLY — not a purchased Aurora lot. Line: CT-AU-12. Designation: TC-ER marking. Construction: 12 conductors, 16 AWG; shielding unknown. Quantity: 240 ft continuous, measured. Condition: removed cable; fitted ends present.
Use this example to build your own records by filling the required evidence fields: printed designation, manufacturer/part number, voltage, conductor count, pair count, gauge, shielding, jacket, fitted ends, specification group, reel ID, continuous length, quantity basis, condition/history, cut-length status, jacket photo, data-sheet reference, unknown field, and photo filename.
Aurora planning context, not a material claim
The task force says infrastructure priorities will consider urgency, impact, feasibility and alignment with city strategic goals, with phased short-, mid- and long-term planning.
That planning statement is local context only; it does not establish that a project used control cable or that any inventory is for sale. The seller task here is narrower: keep each marked control or tray construction and its continuous length on its own evidence-backed line.