Define the offered boundary
Start by stating exactly what is being offered. Separate wire and cable items from installed systems, machinery, conduit assemblies and unrelated equipment. Use an inventory reference for every line or grouped lot and record whether the item is cable-only, cable with attached fittings, or part of an installed assembly.
Include the material category (for example: copper conductor multiconductor power cable, single-conductor aluminum feeder, instrumentation pair) and the included/excluded items (connectors, glands, pull string, conduit). Note storage location and how items are stored—coiled on reels, bundled, loose cutoffs—and whether the lot is staged for review or still inside controlled areas.
Pueblo County lists incentives including the Enterprise Zone, advanced-industry investment tax credit, job-training programs and a Sales and Use Tax Capital Improvement Projects Fund. This local policy list does not identify cable stock, ownership, or a buying outcome; the closeout task remains documenting the offered boundary and authority for the specific material.
- Inventory reference for each offered item or group
- Clear included/excluded list (connectors, conduit, machinery)
- Storage location and current staging status
- Installed vs uninstalled status explicitly stated
Record history and condition
For each inventory reference describe the known service history and be explicit about uncertainties. Distinguish unused stock (never installed), removed cable (installed then removed) and recovery-only material (mixed cutoffs, contaminated pieces or partial lengths). Do not infer new condition from lack of energization—record energization status separately from prior-use history.
Document fitted ends (connected, capped, lugs installed, cut and taped), contamination or visible damage (oil, paint, abrasion, kinking), and give a plain language condition certainty statement: e.g., 'service history incomplete; visible abrasions near terminations; continuous length unconfirmed beyond 120 ft.' Where history is unknown, state that plainly and provide photos of representative sections and the ends.
- Label items as unused, removed, or recovery-only
- Note fitted-end condition and any visible contamination
- State condition certainty level and provide representative photos
- Do not equate never-energized with new
Separate material and weight basis
Keep conductor metal and construction separate in records. Identify copper vs aluminum conductors where known and call out constructions (solid, stranded, concentric, concentric neutral, shielded) and cable jacket types. For mixed cutoff groups, describe typical cutoff lengths and whether continuous runs are present.
Provide weight figures and state the basis: cable-only scale figure, gross weight on reel, or estimated gross. If weight is an estimate, show how it was derived (sample weighings, reel tare subtraction, or scale reading). For recovery-only mixtures, separate long continuous runs from mixed cutoffs in reporting and in any labeling used for on-site staging.
- Conductor metal and construction explicitly stated
- Weight and weight basis for each lot (scale, gross, estimated)
- Cutoff grouping separated from continuous runs
Confirm authority and access
List the owner or legal title holder of the material, and the specific person authorized to grant release for sale or removal. If authority is pending, state that plainly. Do not treat an employee’s ability to show material on-site as authorization to transfer ownership.
Identify site access restrictions, required badges or escorting, and available loading resources (forklift, dock access) and who will coordinate them. Provide a requested timetable for review and any blackout periods where access is not permitted. Be clear that an inquiry does not equate to permission to remove material.
- Owner and named release authority for each lot
- Access restrictions and loading resource details
- Requested review timetable and blackout dates
What to do with unknown or incomplete inventory
If complete records are unavailable, flag the uncertainty and provide the best supporting evidence you have: photographs of ends and lengths, a sample continuous-length measurement, scale figures for representative bundles, and a statement of what remains unknown. We will not assume unknowns; we will use the documented evidence to triage whether a lot can be reviewed, inspected or requires owner confirmation.
When material condition, weight basis or ownership is unclear, propose a staged review plan: 1) provide inventory references and representative photos, 2) allow a site visit by appointment with named release authority present, 3) provide scale tickets or allow on-site weighing and 4) agree on a written release authorization before scheduling removal. These concrete steps reduce risk and align with the resolution to obtain explicit ownership and release authorization before presenting material as available.
- Provide photos, representative measurements and scale figures when records are incomplete
- Propose a staged review: documentation → site visit → weighing → written release
- We will not treat shown material as saleable without written release