Treat underground as a setting, not a specification
Begin with the reel tag and visible jacket legend. Record the product designation, conductor metal and size, marked voltage, and any neutral or shield configuration on the same inventory row. A project name or burial setting can be helpful background, but it cannot establish a cable’s voltage or construction.
Keep unlike markings in separate rows even if reels arrived from one contractor yard. If the neutral or shield detail cannot be read from the available record, use unknown rather than applying another reel’s configuration.
- Reel reference and full product designation.
- Conductor metal and size.
- Marked voltage.
- Neutral or shield configuration, or unknown.
Preserve a per-reel length record
List continuous footage for each reel rather than an aggregate project total. State whether the balance is measured, documented from a tag or estimated, and retain full or partial status. Two reels with the same designation can still have different remaining lengths and different quantity bases.
When a group is genuinely identical, retain individual reel references under the group. This protects the handoff record and lets the reviewer see which tag, image and footage statement belongs to each physical reel.
- Continuous footage per reel.
- Measured, documented or estimated basis.
- Full or partial status.
- Count of genuinely matching reels.
Document physical handoff facts
Photograph the readable marking, reel condition and accessible cable ends where permitted. Record reel dimensions, known gross weight or another explicit weight basis, end protection and known storage exposure. These are inventory facts, not a promise about handling or condition.
Identify the private owner, release authority, storage access and relevant loading restriction. A marked distribution reel is not ready to be treated as offered until the technical record and the release record point to the same item.
- Jacket and tag photo reference.
- End condition and known storage exposure.
- Dimensions and stated weight basis.
- Private release authority and access limits.
Keep an incomplete reel reviewable
If voltage, neutral or footage is unknown, do not replace the field with a generic distribution label. Preserve the portion of the legend that is readable, attach the associated photo and state exactly what remains unknown. This avoids the common mistake of giving every reel the same project-level configuration.
Illustrative inventory example—not a purchased lot: UD-CC-04 is a fictional warehouse reel with a photographed designation, 580 ft documented, gross weight including packaging, and conductor weight unknown. The example separates the known length from the unresolved weight basis.
- Unknown voltage or neutral remains an explicit field.
- Do not copy one reel configuration to another.
- Distinguish gross weight from conductor weight.
Keep Cape Coral context limited to source documentation
The UEP page says Cape Coral’s potable water comes from deep wells in the Lower Hawthorn Aquifer, and its wastewater system uses gravity sewer lines, lift stations and force mains to reclamation facilities.
That infrastructure description may be useful background when a private seller explains a record, but it does not show that a particular reel served the system or belongs to the city. The offered material still needs its own marked configuration, present balance and private release authority.
- Use public infrastructure only as context.
- Document the offered reel from its own tag and records.