Anchor the record to the marked kV reel
Photograph and transcribe the actual kV marking, manufacturer, precise part number, and reel ID for every reel. A broad voltage label in a project file or a similar-looking reel nearby is not a substitute. The goal is one traceable record in which the continuous length and cable designation are tied to the same physical reference.
If part of the marking is unreadable, identify the legible text and retain the gap. Do not fill it from another reel. A line that openly states an unknown rating field is more reliable than a line that borrows a plausible specification.
- Marked kV, manufacturer, part number, and reel ID.
- One continuous-length field per physical reel.
- Readable marking images paired to the same reference.
Match construction and records without borrowing facts
Record insulation level, shield or neutral construction, and conductor metal or size only where jacket text or a matching data sheet supports the exact reel. For a production or existing test record, capture batch ID, record date, scope, and whether the reel match is confirmed. A record for another batch should be retained as a mismatch, not copied into the offered line.
This prevents a common error: assigning one reel another reel’s kV rating or record history. When the link is not established, leave the construction or record field unknown and state what would be needed to verify it.
- Insulation, shield or neutral, and conductor details tied to matching evidence.
- Batch ID, record date, and scope.
- A confirmed, unconfirmed, or mismatched reel relationship.
Describe physical history without a fitness claim
For each reel, record continuous length, end protection, known moisture exposure, storage history, and visible condition. State whether the material is uninstalled or has prior history only when that information is documented or observable. A photo of an end cap, jacket, or flange is useful condition evidence, but it does not certify performance or determine a purchasing outcome.
If storage dates, end condition, or exposure history are incomplete, write unknown. Keep those gaps with the reel ID so they are not silently replaced by observations from another reel in the same yard.
- End protection status for both accessible ends.
- Known moisture exposure and storage history.
- Visible condition with unknowns kept explicit.
Keep the FDOT reference in its proper scope
FDOT’s Central Broward Transit archive includes a South Florida Education Center/Davie working-group document and a Town of Davie update among its project presentations and working-group materials.
That fact is limited Davie-area planning context. It does not establish a present cable project, voltage class, cable specification, ownership, or supply. The appropriate evidence for a medium-voltage cable line is the marked reel and its matching records, not a project reference.
- Do not use a project archive as a reel specification.
- Retain rating and batch traceability at the individual-reel level.
Illustrative medium-voltage reel record
Illustrative fictional record—not a purchased lot: MV-DV-05 has a 15 kV marking photographed, with insulation level unknown. The record lists 720 ft documented, an uninstalled reel, one missing end cap, and no matching test record. Each uncertainty remains in the line instead of being filled by a nearby reel or a general voltage label.
If the seller later locates a record, it should identify MV-DV-05 or its matching batch before it is associated with the line. If it does not, retain the mismatch and do not change the unknown field. This example is not an offer, acceptance decision, or a claim about cable performance.
- Reference: MV-DV-05.
- Identification: 15 kV marking photographed; insulation level unknown.
- Quantity: 720 ft documented.
- Condition: uninstalled reel; one missing end cap; no matching test record.
