Verify the metal from a record
Transcribe the jacket legend, reel tag, or matching product document that identifies the conductor metal. Record the manufacturer, product designation, and AWG or kcmil size with the source of identification. A silvery surface alone is not enough to establish aluminum because construction and coatings can complicate appearance.
If no reliable record is available, use metal unconfirmed and preserve the visible clues as notes. This is more actionable than guessing because it identifies exactly what needs confirmation without turning a photograph into a material certification.
- Conductor metal or unconfirmed status
- Manufacturer and product designation
- AWG or kcmil and identification source
Separate assemblies before describing quantity
Keep bare conductors, insulated single conductors, multi-conductor cable, and mixed-metal assemblies on different lines. Preserve the conductor count, insulation, and any neutral, shield, armor, or support detail. A line that includes several metals should say so instead of being assigned a single metal total.
This page consolidates copper and aluminum into one decision because both require the same separation discipline. It is not a generic surplus reconciliation: the focused question is whether each line’s metal and construction are documented well enough to distinguish it from the next line.
- Construction type
- Conductor count and insulation
- Neutral, shield, armor, or support detail
Label the quantity basis exactly
Record continuous footage and weight as different fields. State whether a weight is cable-only, gross loaded-reel, net, or estimated, and identify the measurement source. Do not report a loaded wooden reel’s scale figure as conductor weight when the reel, insulation, and other components are included.
The common error is a 900-pound loaded reel described as 900 pounds of copper while an exposed silvery conductor is described as aluminum without records. The fix is simple: retain the scale figure, label its basis, and leave conductor weight or metal unconfirmed where the record does not support it.
- Continuous length
- Weight value and weight basis
- Measurement source
Keep identified lengths apart from mixed pieces
List identified long lengths separately from short mixed pieces or incomplete material. Describe visible contamination or insulation conditions and state the storage location and release authority. This prevents a small uncertain group from changing the description of an otherwise documented reel.
Miami-Dade Public Works says the county maintains approximately 5,500 miles of dedicated public roads, about 195 vehicular or pedestrian bridges and about 168 miles of secondary canals. That county fact is limited local context for careful infrastructure-style inventory records; it does not establish that any offered material came from public assets.
- Identified cable inventory versus mixed pieces
- Visible contamination note
- Storage location and release authority
Use a fictional line to test the listing
A fictional record, CU-AL-MB-01, might show an identified insulated copper reel at 640 documented feet and a separate aluminum feeder line at 275 estimated feet. It could show 1,020 pounds as gross loaded-reel weight while conductor weight remains unknown. This is only a formatting example, not a purchased lot.
If a row cannot say whether its number is footage, cable-only weight, or gross loaded-reel weight, split it before sending. The same check applies when an identification source is missing: the correct value is unconfirmed, not a metal guess.
- Example reference: CU-AL-MB-01
- Separate copper and aluminum lines
- Conductor weight may remain unknown
