What we need first — marked rating and identity
The single most important item for each offered reel is the reel-level marking: the exact kV stamped or printed on the jacket or reel legend, the manufacturer name, and the complete part number. Photograph each marking clearly and transcribe it exactly; do not substitute a generic voltage category (for example, “medium-voltage”) for the marked kV. If any of the required fields are missing on an offered reel, leave them unknown and state that the reel lacks that evidence rather than replacing it with a similar reel’s data.
If the jacket legend and reel tag conflict, note both in your submission, include images of both legend and tag, and state which one is physically attached to the reel and which appears to be a later addition or separate document. We will treat conflicts as incomplete traceability until a matching manufacturer or batch record confirms the correct value.
- Required: marked kV, manufacturer, complete part number, jacket legend transcription
- Include clear photos of the reel tag and any printed jacket legend (but photos are descriptive only)
- If a field is absent or contradictory, mark it unknown and describe the discrepancy
Construction and shielding — record what’s documented
Report conductor metal and size, insulation class, shielding or neutral arrangement, and any construction details only when shown on the reel marking or on a manufacturer record explicitly matched to that reel. Do not infer construction from a look-alike reel or from a project description. Where a manufacturer construction record exists and matches the reel ID or batch, include the record reference and the exact fields it confirms.
If you cannot locate a matching manufacturer record, leave those construction fields blank and state that construction source is not found for the specific reel ID.
- List conductor metal/size, insulation level, shield/neutral only when supported by reel marking or matching manufacturer record
- Attach or reference the construction source when it explicitly names the reel ID or batch/lot ID
Batch, test and production records — link by reel ID
Match production, batch, lot or factory test records to each offered reel by reel ID, batch/lot ID and record date. State clearly whether the record covers the exact reel, a batch that explicitly includes the reel ID, or is absent. If no matching records exist, declare that explicitly rather than attaching project-level paperwork that does not name the reel or batch. Distinguish whether stock is unused (still on original reel with full length), partly used (reel shows removed footage), or removed stock (sections cut from reels).
Where matching records are attached, specify the scope and date range of those documents. If a test record covers multiple reels, show the batch ID and list which reel IDs are included.
- Provide reel ID, batch/lot ID, record date/scope, and service status for each reel
- State clearly when no matching production/test records are found
- Differentiate unused, partly used, and removed stock in your listing
Ends, storage and physical condition — descriptive reporting
Describe continuous footage and whether ends are protected and accessible. Report any visible moisture exposure or damage, and note dimensions plus gross or estimated net weight for logistics planning. Photographs may show visible damage or missing end protection but are not evidence of electrical fitness; do not use photos to claim test status.
If you cannot determine continuous footage because the reel is partly used or unmarked, indicate that footage is estimated and state the basis for the estimate. For unknown storage history, mark storage exposure as unknown rather than presuming indoor or covered storage.
- Report continuous footage, end protection, storage exposure, dimensions, and gross/net/estimated weight
- If footage is estimated, explain how you estimated it
- Photographs describe condition only; do not substitute them for matching batch test records
Palm Bay utility context is not reel traceability
The city Utilities page provides links for water, wastewater and reclaimed-water services, an interactive service-availability map, and engineering and construction information.
Those city resources make utility or construction records a possible seller context only. They do not establish a medium-voltage cable’s rating, ownership, condition, test history, or availability; those facts must remain tied to the specific reel or batch.
What to do when inventory or records are incomplete
If a reel lacks one or more of the required evidence fields (marked kV, manufacturer, part number, jacket legend, reel ID, or matching batch/test records), do not fill those fields with a similar reel’s data or with project descriptions. Instead: 1) mark the absent fields as unknown; 2) describe the discrepancy and any conflicting markings; and 3) attach only records that explicitly reference the same reel ID or batch/lot ID. This honest inventory state keeps traceability clear and avoids the mistake of substituting presumed identity from look-alike reels.
When records are incomplete, note what you searched (manufacturer archives, project paperwork, onsite tags) and give the results. If you can reasonably add a reel-level identifier (for example, a photographed reel tag number) do so; if none exists, state that a reel ID is not present and leave batch/test fields empty.
- Mark unsupported fields unknown and describe conflicts
- Attach only records that explicitly reference the same reel or batch