Treat the printed designation as the starting point
Multi-conductor reels can look nearly identical while differing in conductor count, pair count, gauge, shielding, voltage marking, or jacket. Copy the full readable jacket legend and manufacturer part number before sorting the cable. Retain Type TC, TC-ER, PLTC, or another exact designation only when it is actually printed or supported by a matching record.
The specific mistake this page corrects is calling every cable from a tray or utility area Type TC. Storage location does not establish construction. Put unreadable or partially readable material on an unknown line with photos of the readable segments rather than completing the legend from another reel.
- Record printed designation, manufacturer, part number, and voltage marking exactly as observed.
- Use separate fields for conductor count, pair count, size, shielding, and jacket.
- Keep a partially readable label as partially readable; do not invent missing characters.
Apply a narrow local-context statement
The city Utility Systems page lists commercial development and utility engineering services and describes a well project involving nine raw-water supply wells and about 3.5 miles of raw-water main piping. This is limited city infrastructure context only; it does not identify control or tray cable stock, establish a product type, or support a statement about buyer demand.
The product decision belongs to the offered cable. The seller should use the reel label, jacket marking, and any matching record to separate close specifications before a buying inquiry is submitted.
- Do not use a city source to fill a product field.
- Keep location context separate from designation and construction evidence.
- Use the same inventory reference for the reel, photo set, and matching document.
Split close specifications before grouping reels
Create a new row whenever conductor count, pair count, size, shielding, jacket, or printed designation differs. For example, an overall-shielded 12-conductor 16 AWG reel and an unshielded reel with the same count and size remain different inventory lines. An apparently similar exterior jacket is not enough to merge them.
If a reel has mixed or uncertain internal construction, leave shielding or pair count unknown and preserve its own line. This is more actionable than a broad “control cable” total because it shows exactly which field needs confirmation.
- Do not combine unshielded and shielded reels under one description.
- Keep pair count distinct from total conductor count.
- Preserve jacket and voltage-marking differences even when the part numbers look similar.
Record footage, fitted ends, and evidence links
For each line, record reel ID, continuous footage, and whether the amount is measured, documented, or estimated. Then note whether ends are fitted or bare, describe the visible condition, and attach photo references. A fitted-end note is not a reason to alter the cable; it is simply an inventory field.
Match any data sheet to the exact line. When a document cannot be tied to the reel, label it unmatched rather than treating it as a confirmation. Unknown fields are useful because they prevent a product-specific claim from resting on a generic cable description.
- Use reel ID, continuous footage, quantity basis, fitted ends, photo references, and condition.
- Label a document as matching, unmatched, or unavailable.
- Keep the estimated-footage method in the same row as the estimate.
Illustrative control-cable record
This fictional example is a record template, not a purchased Port St. Lucie lot. It demonstrates that the count and a known Type marking may be shown while an unsupported shield field stays unknown.
A real line should carry the same reference in the photo filenames and any manufacturer document so the construction evidence can be checked without borrowing a nearby reel’s details.
- Line: CT-PSL-03.
- Identification: TC-ER marking photographed; 12 conductors, 16 AWG.
- Quantity: 240 ft measured continuous; fitted ends present.
- Shielding: unknown; no matching product record attached.
- Condition: seller-reported previously used cable; jacket photo linked to the line.