Why precise designation matters
Control and tray cables often look similar on a reel but differ in fundamental construction and permitted use. Buyers evaluate physical markings—printed designation, voltage rating, and part numbers—rather than where the cable was stored or last installed. Accurate designation prevents misclassification and protects both parties during review and matching to product datasheets.
When designations are unreadable or missing, record that field as unknown and collect supporting evidence (photos, reel labels, measurements). Treat unknown designations as incomplete records rather than assuming a type based on storage location.
- Record the printed designation exactly (e.g., TC, TC-ER, PLTC) rather than inferring from installation location.
- Do not use storage or tray vs. conduit location as the product type.
- Mark unreadable or absent printed fields as unknown and provide photo references.
Step-by-step documentation workflow
Follow the brief steps in order so every reel or cut length can be evaluated separately. First transcribe the designation and any manufacturer markings. Next, split inventory lines by construction differences such as conductor and pair counts, gauges, shielding presence, and jacket type. Then record each physical piece with its reel ID, continuous footage, and any fitted ends or damage. Finally, attach related photos, datasheet references and label unverified fields unknown.
This workflow reduces ambiguity: a single storage location may contain both TC-ER and non-ER control cables, different gauge conductors, or mixed shielded and unshielded constructions. Each distinct construction must have its own inventory line.
- Transcribe the designation: printed designation, manufacturer, part number, voltage marking.
- Split constructions: conductor count, pair count, gauge, shielding, jacket.
- Record each piece: reel ID, continuous length, measured/documented/estimated basis, fitted ends, damage.
- Match documentation: photo references, data-sheet reference, unknown fields, service history.
Handling unreadable or incomplete markings
If markings are partially or fully unreadable, label those fields 'unknown' and increase other supporting evidence: close-up photos of jacket and any label remnants, measured conductor gauge, and footage. Note whether length is measured, documented, or estimated. Do not convert unknown markings into a presumed type based on where the cable was found.
When you cannot supply the printed designation, describe what you can verify—manufacturer imprint fragments, conductor count and gauge, shielding presence—and attach photos that show the best available evidence. This honest approach keeps inventory lines accurate and makes the next review question easier to identify.
- Label unreadable printed designations as unknown and attach photo references.
- Provide measurement basis: measured, documented, or estimated.
- When in doubt, keep the designation unknown rather than assuming Type TC because the cable was in a tray.
How to split similar-looking reels on separate lines
Create a distinct inventory line whenever any of the required construction evidence fields differ. For example, a 12-conductor 16 AWG unshielded reel and a 12-conductor 16 AWG reel with foil/braid shielding are separate lines even if the external jacket color and reel size match. Likewise, pair-count differences (e.g., 6 pairs vs. 12 conductors individually) and fitted ends should be tracked per-piece.
Include reel identifiers and continuous footage per line so evaluators can match photos and labels to a specific piece. If multiple physically contiguous reels share identical, verifiable printed markings and construction, they may be grouped with a combined continuous footage field and a list of reel IDs; otherwise keep them separate.
- Different conductor or pair counts => separate lines.
- Different shielding or jacket material => separate lines.
- Different fitted ends or damage status => separate lines.
Illustrative record and how to use it
Use the provided illustrative record as a formatting example when preparing submissions. It shows the minimum fields and phrasing we expect when a reel includes a marking (TC-ER), conductor count, gauge, unknown shielding, continuous footage and condition notes about fitted ends.
Do not treat the illustrative record as an offered lot; it exists only to demonstrate how to report the required evidence fields. When you prepare your actual record, include all required evidence items listed in the seller task.
The City homepage provides links to engineering projects, maps/GIS, parking and mobility information and commercial solid-waste guidance. Those links are general city context, not evidence of a cable project or seller; a submission still needs seller-supplied storage, access, and product-identification details.
- Example label: CT-WPB-01; description: TC-ER marking, 12 conductors, 16 AWG; shielding unknown; quantity: 240 ft continuous, measured; condition: removed cable; fitted ends present.
- Follow the same field names and attach photo references and data-sheet references where available.
What to do with unknown or incomplete inventory
If an inventory item lacks required evidence, report every known attribute and flag all unknown fields explicitly. Provide photos of reel flanges, jacket print, fitted ends, and any label remnants. State the basis for footage (measured, documented, or estimated). This transparent recording lets evaluators decide whether on-site verification, further record review, or a conservative unknown designation is necessary.
Do not attempt to reclassify unknown items by installation location. The provided resolution in the brief requires using actual markings and matching records; unsupported designations should remain unknown until corroborated.
- Report all known fields and explicitly list unknowns.
- Attach photos for unreadable or partial markings.
- Provide measurement basis and reel IDs to permit later verification.