Transcribe the designation that is actually printed
Begin each line with the visible jacket designation, such as TC, TC-ER, PLTC, or other wording exactly as it appears, then add manufacturer, part number, and marked voltage if present. Where the legend is incomplete, capture the readable portion in photos and mark the designation unknown rather than assigning a familiar category from storage location.
Cable placed in a tray is not automatically Type TC. The inventory task is to preserve what the product says about itself, not to infer a designation from where it was installed or stored.
- Exact jacket designation
- Manufacturer and part number when visible
- Marked voltage and readable jacket legend photos
Separate the differences inside similar assemblies
Create separate lines whenever conductor count, pair count, gauge, shielding, jacket, or fitted ends differ. A reel with 12 conductors at 16 AWG and unknown shielding is not interchangeable with an otherwise similar reel that has a documented pair count or different shield arrangement. Keep unknowns in their own field so they do not disappear in a combined description.
The likely inventory mistake is merging every removed cable from a tray under one Type TC label. The resolution is to use actual markings and manufacturer records, leaving unknown designation and every differing count, gauge, or shield arrangement separate.
- Conductor count and pair count as separate fields
- Gauge, shielding, jacket, and fitted-end differences
- A separate line whenever an identification field is unknown
Tie partial lengths to the physical reel
List each full reel, partial reel, and cutoff with a reel ID or assigned reference, continuous length, and quantity basis. If several pieces came from the same reel, identify the origin but keep the pieces as separate lengths. Do not present a sum of cutoffs as one continuous run.
Use measured, documented, or estimated as the quantity basis. When footage is estimated, state why and retain the photographs and reference that could support a later measurement. This turns an incomplete line into an honest one instead of an assumed specification.
- Reel ID or assigned reference
- Full, partial, or cutoff status
- One continuous length and its quantity basis
Record source and condition without deciding suitability
State whether the item is uninstalled maintenance stock, project overrun, or removed material, and note any known service history, visible jacket damage, and matching documents. Describe fitted ends as observed; do not turn a condition note into a performance claim. A data sheet or work record belongs with the same reel reference it actually covers.
UGA Facilities Management says more than 800 personnel manage, operate and maintain campus landscapes, buildings and infrastructure.
This is limited local facilities context, not a statement that UGA owns, offers, or endorses any cable. It explains why a seller should keep facilities-origin notes and construction records with the actual control or tray cable line.
- Source or status: uninstalled, overrun, or removed
- Visible jacket condition and fitted ends
- Record-match status for data sheets or work files
Worked example and a practical submission route
Illustrative fictional inventory example—not a purchased lot: CT-A-01; TC-ER marking; 12 conductors, 16 AWG; shielding unknown; 240 ft continuous, measured; removed cable with fitted ends present; part-number data sheet not yet matched. The record does not relabel the unknown shield or assign the reel a different product family.
For an Athens inquiry, keep photo filenames tied to CT-A-01 or the seller’s own reference, then send the inventory and photos to saleselectricalbuyers@gmail.com or use the quote form. Include the release contact and any site-access constraint as a fact to be clarified, not as an assumed movement arrangement.
- Photographs of printing, reel, and fitted ends
- Unmatched documents marked as unmatched
- Release contact and access facts stated separately
