Capture the actual legend before assigning a cable type
Photograph readable jacket printing and transcribe the designation exactly. Type TC, TC-ER, PLTC, and a manufacturer part number are item-level identifiers; the tray, automation cell, or building where the cable was found is only context. When printing is incomplete, record the readable portion and mark the rest unknown.
Johns Creek's Economic Development Department identifies healthcare, life sciences and innovation as target industries. That city fact can explain why a facility inventory may include automation-related records, but it does not prove a cable type, identify a local seller, or support an assumption about available material.
- Assign a reel reference before taking photographs.
- Capture the jacket legend and tag separately when both exist.
- Keep a manufacturer sheet only when it can be tied to the same reel.
Split configurations that only look alike at a distance
Use separate rows when conductor count, pair count, gauge, shielding arrangement, jacket, or designation changes. For multi-pair products, state both the total conductors and the pair count if those are known. Describe shielding as shown in records or marking; do not infer an overall or individual shield from the cable’s location.
This separation is especially important when several reels were removed from one tray or cabinet. A shared origin does not make their configuration identical, and combining them into one footage total can conceal the distinctions a buyer needs to evaluate.
- Record conductor count and pair count in distinct fields.
- Describe shield status as documented, unknown, or not shown on the available record.
- Create another line when gauge or jacket wording differs.
Keep length, ends, and condition beside the configuration
For each reel or cut length, state the remaining continuous footage and whether the figure is measured, documented, or estimated. Identify full reels, partial reels, and cut pieces separately. Record fitted ends and visible jacket damage without presenting a photograph as proof of electrical condition.
Do not total short pieces as if they formed one usable run. A seller can describe them in the same inquiry, but their individual lengths and condition notes should remain visible. This is different from a bulk-lot workflow, where site aggregation is the principal decision.
- Use one quantity basis for each reel or continuous piece.
- Note fitted ends separately from the cable designation.
- Keep removed cable distinct from uninstalled stock.
Match each technical record to its reel
Name images, labels, and existing documents with the reel reference. A product sheet should be marked matched only when its part number or designation can be connected to the visible reel evidence. If the connection is partial, state what matches and what remains unconfirmed.
When the jacket cannot be read, add a close photo of the limitation, retain any tag image, and create a designation-unknown row. That approach lets a reviewer see the evidence gap without converting a likely classification into a fact.
- Use a tag photo, jacket photo, reel overview, and end photo when available.
- Mark document matching as matched, partial match, or unconfirmed.
- State which configuration field is unknown and why.
Worked control-cable record
Illustrative inventory example—not a purchased lot: JC-CT-03 has a TC-ER marking, 12 conductors, 16 AWG, shielding unknown, and 240 feet continuous measured; it is recorded as previously used cable with fitted ends present. This fictional record illustrates why a seller should preserve a known legend and an unknown shield status in separate fields.
Add the seller’s material location, release authority, and access constraints to the inquiry after the configuration is clear. Those facts help describe the offered cable but do not change the identity of the particular reel.
- Example reel reference: JC-CT-03.
- Example configuration: 12 conductors, 16 AWG; shielding unknown.
- Example length: 240 feet continuous, measured.