Read the assembly rather than the former location
Cable found in a tray is not automatically Type TC. Photograph and transcribe the actual jacket designation, manufacturer, part number when available, and marked voltage. The same storage location can contain several assemblies with different conductor counts, shield arrangements, or jackets.
Bloomington’s economic-development office says the city supports agricultural, healthcare, financial-services, manufacturing, distribution and retail businesses. It is city context for a possible commercial inventory conversation only; it does not show that an identified plant, warehouse, or cable lot exists.
- Record TC, TC-ER, PLTC, or the exact printed designation.
- Photograph the entire readable legend rather than one abbreviation.
- Make a separate unknown line for unreadable markings.
Separate conductor and shield patterns
Create separate lines for each conductor count, pair count, gauge, shielding arrangement, and jacket detail. Similar color or common former location is not a reason to merge cable with different constructions. A pair-count difference or a foil-versus-braid shield can be material to the record even when the reels look similar from a distance.
If shielding is uncertain, write unknown and attach the evidence that remains. Do not classify an assembly from a tray label, a nearby data sheet, or an assumed pattern. The task is to make construction differences visible before the cable is presented for review.
- Use separate fields for conductor count, pair count, gauge, shield, and jacket.
- Keep each marked voltage with its matching assembly.
- Do not use a tray location as a technical designation.
Preserve each continuous piece
For every reel or continuous cut length, record a reel or cut ID, continuous footage, quantity basis, fitted ends, and visible jacket damage. Matching reels can share a product description only if each reel’s own footage and end condition remains visible. Two cut pieces should never be described as a single longer piece.
A fictional example is: line CT-BLM-01; marking TC-ER, 12 conductors, 16 AWG; shield unknown; quantity 240 ft continuous, measured; condition prior-use cable, fitted ends present. It is an illustrative inventory example—not a purchased lot.
- State measured, documented, or estimated continuous footage.
- Photograph fitted ends and any visible damage without altering the cable.
- Keep prior-use status separate from uninstalled stock.
Link source, photos, and release authority
Record whether each line is uninstalled stock, project overrun, or material with prior use. Match photographs and data sheets to the exact line, then identify the release authority or write authority pending. A data sheet for a different conductor count should not be used to complete an unknown line.
If information is incomplete, list what is missing, preserve the item as a separate record, and explain the basis for any estimate. That approach resolves uncertainty without implying an acceptance decision or a technical condition conclusion.
- Match photo references to line ID.
- Keep source status and release authority in separate fields.
- Keep unmatched records outside confirmed technical fields.
Correct the “everything in a tray” error
The likely mistake is classifying all cable formerly routed in a tray as Type TC and combining it into one total. That loses the actual designation, conductor or pair pattern, shielding, and continuous length. It can also hide fitted ends or jacket differences that belong on their own lines.
Correct it by using the actual marking and matching record, splitting conductor or pair counts and shields, and retaining each continuous piece. Send the separated list and photos to saleselectricalbuyers@gmail.com, or call +1 (614) 715-3047 with record-preparation questions. Submitting the list does not promise acceptance, price, or a handling arrangement.
- Use actual markings, not tray location, as the type field.
- Keep unmatched construction fields unknown.
- Preserve each continuous piece and fitted-end note.