Use jacket markings before location labels
Cable found in a tray is not automatically one product type. Transcribe the actual Type TC, TC-ER, PLTC, or other printed designation from the jacket and tie it to a reel or cut-length reference. A former location or tray label is context, not a product specification.
When printing is unreadable, record designation as unknown. Do not make a Type TC claim from the cable’s storage position, color, or nearby equipment.
- Printed designation
- Manufacturer and part number
- Marked voltage
- Reel or cut-length ID
Split the small construction differences that change a line item
Keep different conductor counts, pair counts, gauges, shields, and jackets on separate inventory lines. Reels can look alike while carrying different control functions or construction details. The seller record should make those differences visible instead of creating one combined total.
Where a shield is present, state the documented form; where it is not supported by the marking or record, use unknown. The same approach applies to pair count and jacket detail.
- Conductor count
- Pair count
- Gauge
- Shielding and jacket detail
Keep continuous pieces and fitted ends visible
Record the continuous length of each full reel, partial reel, or cut piece with a measured, documented, or estimated basis. Two short lengths should not be added and described as one longer continuous piece.
Note fitted ends and visible condition as observations. Include a photo reference for the reel, jacket print, and any relevant end or jacket detail so the inventory line can be checked without assuming all pieces are identical.
- Continuous length
- Quantity basis
- Full, partial, or cut form
- Fitted-end and condition observation
Describe history and incomplete markings honestly
State whether the line is uninstalled stock, previously used cable, or another known condition. Record the storage location and release authority separately. If fields are unavailable, name them as unknown and keep the item apart from fully identified inventory.
Do not use another reel’s markings to complete an unreadable line. A transparent unknown field preserves the opportunity for a later record match without overstating the material description.
- Service-history statement
- Unknown fields
- Storage location
- Release authority
Use Elgin context and a specification-separation example
The City of Elgin says its new commercial/industrial construction and addition application is also used for commercial/industrial tenant build-outs and projects involving multiple contractors. The fact provides limited project-record context only; it does not show that any local tray or control cable is available, owned, or suitable for a buyer.
Illustrative fictional record: CT-ELG-05 carries a TC-ER marking, 12 conductors at 16 AWG, shielding marked unknown, 240 ft measured as one continuous piece, and fitted ends observed. It shows a specification-specific line and is not an actual or purchased lot.
- Classify from a verified marking
- Keep unknown designation separate from a confirmed specification