Start with a documented feeder designation
Photograph and transcribe the manufacturer designation, part number, and conductor-metal statement on the tag or jacket. Record what the actual product document says; do not use cable diameter, color, or a nearby reel as a substitute for the offered assembly.
An assembly can contain neutral, shield, support, or plated components that need their own description. If the product record does not identify one of them, list it as unconfirmed rather than extending a single metal label across the whole cable.
- Manufacturer designation and part number
- Exact metal statement or “metal unconfirmed”
- Data-sheet reference matched to the reel
Preserve the assembly, not just the largest conductor
Record AWG or kcmil, conductor count, neutral details, shield or support details, insulation, and marked voltage wherever documented. Retain the wording from a matching tag or product record so different feeder assemblies do not become one generic line.
Do not infer a neutral or support construction from an exposed end. When a field cannot be established without changing the cable, leave it unknown and identify the photo or record that supports the remaining fields.
- Size and conductor count
- Neutral, shield, and support description
- Marked voltage and insulation where shown
Report current footage and condition separately
For every reel, record the current continuous length and whether it is measured, documented, or estimated. An original tag quantity may describe a full reel while the remaining material is partial. State both only when their relationship is clear.
Describe end condition, reel integrity, storage exposure, and whether the stock is uninstalled or previously used. A visible end can document condition; it does not prove the composition of hidden components.
- Reel ID and continuous footage
- Measured, documented, or estimated basis
- End condition and storage exposure
Include handling facts and restrained local context
Provide reel dimensions, gross/net/unknown weight, access limits, and available loading resources as facts about the site. Do not treat those details as an agreement about movement or acceptance.
Naperville’s Electric Utility mission includes operation, maintenance and replacement activities and a capital-improvement program; the city reports 106 million kilowatt-hours consumed in September 2025. It is context for a private seller’s maintenance or replacement description, not evidence of a city-owned aluminum feeder lot.
Illustrative feeder record
This fictional record demonstrates an explicit estimate and a documented neutral detail. It is not an actual or purchased Naperville lot.
In a real record, retain the same reel reference in photographs, the inventory line, and any matching product document. Keep unresolved metal or footage fields conspicuous.
- Reference: AL-NAP-04
- Designation: aluminum feeder designation from reel tag; 4/0 AWG
- Quantity: 275 ft continuous, estimated
- Condition: partial reel; exposed end noted; neutral construction documented