Capture the exact jacket designation
Photograph and transcribe TC, TC-ER, PLTC, or whatever designation actually appears on the jacket. Include manufacturer, part number, voltage marking, and photo reference. A cable’s tray location does not establish a type designation.
When printing is unreadable, keep the reel on its own “designation unknown” line. Record the visible attributes without assigning a type from appearance, storage aisle, or a similar reel.
- Printed designation and readable legend
- Manufacturer and part number when present
- Photo reference for each line
Separate counts, pairs, and shields
Control and tray cable can differ in conductor count, pair count, gauge, foil or braid shielding, drain arrangement, and jacket. Split the inventory when any of those attributes differs, even if reels appear identical from a distance.
Do not use one confirmed reel to describe neighboring reels. A separate line with an unknown shield or pair count is more accurate than an aggregated total that hides the distinction.
- Conductor count and pair count
- Gauge and shield detail
- Jacket and marked voltage
Document remaining pieces without changing them
Record each reel or continuous cut length, footage basis, fitted ends, visible jacket condition, and known history. If length is estimated, state the method; if a field cannot be seen without altering the cable, keep it unknown.
List uninstalled stock and previously used cable separately. Photographs of accessible ends and jacket condition document what is visible but do not prove electrical fitness.
- Reel or line ID and continuous footage
- Measured, documented, or estimated basis
- Fitted ends, damage, and history
Connect records to authority and local context
Match data sheets, job records, and photos to the line reference, then record owner and release authority. A blank authority field should be marked unknown, not assumed from a storage location.
Naperville’s Electric Utility mission includes operation, maintenance and replacement activities and a capital-improvement program; the city reports 106 million kilowatt-hours consumed in September 2025. That statement is limited local context; it does not prove the source, specification, or availability of any control or tray cable.
Illustrative control-cable record
This fictional entry keeps the known designation and footage alongside an unknown shield field. It is not an actual or purchased Naperville lot.
For a real item, use its reference in every photo and record so an unreadable marking or unconfirmed construction does not become a claim about the rest of the lot.
- Reference: CT-NAP-06
- Designation: TC-ER marking; 12 conductors, 16 AWG
- Quantity: 240 ft continuous, measured
- Condition: previously used cable; fitted ends present; shielding unknown