Step 1 — Capture the complete designation
Record the printed or stamped designation exactly as it appears on the cable jacket or label. Note Type MC, MC-HL, TECK or any manufacturer part number and the full designation text. Include conductor metal, count and size as printed, the marked voltage, and any jacket printing or color codes.
Photograph the label or jacket printing close enough to read letters and numbers. If a label is partially torn or obscured, capture the best available image and transcribe the visible characters literally. For assemblies that list a manufacturer or part number, capture that entry verbatim so a reviewer can match the printed designation without dismantling the cable.
- Evidence fields to supply: designation, manufacturer/part number, conductor metal/count/size, marked voltage, jacket
- If a full designation is unavailable, record the partial text and mark the missing sections as unknown
Step 2 — Describe armor and external condition without dismantling
Do not cut, strip or otherwise open the assembly to inspect internal conductors. Instead, photograph and describe all accessible external surfaces: armor, outer jacket, cable ends, and any visible terminations or fittings. Note crushed sections, kinks, corrosion on metal fittings, broken or missing glands, exposed conductor ends seen only at terminations, and evidence of heat or charring.
Provide close and wide-angle photos of each reel, spool end, and any damaged sections along the length so a reviewer can judge whether visible damage intersects critical areas. State whether the ends appear factory-terminated, field-fitted, or cut, and describe the fittings and terminations that are visible without disassembly.
- Evidence fields to supply: armor condition, jacket condition, fittings/terminations, visible damage, service history
- Do not claim internal conductor condition or electrical fitness from an intact exterior
Step 3 — Separate lengths and state weight basis
List full reels, partial reels and removed cut lengths separately. For each reel or bundle, provide a reel or line identifier, the continuous length when known, and the condition of that length. If lengths are estimated, mark them clearly as estimates and explain the method used (e.g., reel label, measured end-to-end, vendor documentation).
When reporting weight, label it as gross, gross with unknown conductor weight, or unknown. Do not convert gross assembly weight into conductor weight unless the record includes a manufacturer specification or verified teardown data. Keeping the weight basis explicit prevents confusing loaded assembly weight with conductor-only weight.
- Evidence fields to supply: reel/line ID, continuous length, condition, weight basis, quantity basis
- If quantity is mixed (full reels plus cut lengths) separate lines and supply a count for each line
Step 4 — Confirm release, access and loading details
Before discussing lot-specific movement or terms, state the physical storage site, any access limits or permits required, available loading resources, and who is authorized to release material. A buyer needs to know whether the lot sits on private property, in municipal storage, or behind a gate and whether special lifting gear is required.
Peoria Public Works reports responsibility for 493 miles of streets, 80 miles of alleys and 9,000 storm sewer inlets; Engineering oversees right-of-way permitting. That fact is limited public-infrastructure context, not proof that a seller has access to a municipal site or authority to release cable. For an actual lot, state the private storage location, access limits, available loading resources, and the role that can authorize release.
- Evidence fields to supply: storage site, access limits, loading resources, release authority
- If access or release is restricted, include contact points or the steps required to gain access
What to do with unknown or incomplete inventory
If designation fields, lengths, or weight bases are unknown, disclose each unknown field instead of guessing. For example: “conductor count unknown — label partially unreadable; weight reported as gross assembly weight.” Provide photographs that show the unreadable label area, and note any attempts made to read or clean the marking.
When internal conductor details are not visible, avoid stating conductor metal or usable length as facts. State whether the assembly was unused, factory-new, or removed from service according to the best available records; where service history is missing, mark service history as unknown. This approach follows the resolution to record the printed assembly and history, disclose visible damage, and keep gross weight labeled correctly.
- If you cannot confirm internal conductor condition, do not assert electrical fitness or reuse approval
- Label all unknowns clearly to reduce back-and-forth during evaluation
Illustrative record example
A fictional inventory record—not a purchased lot—could read: AR-POR-06; Type MC tag; three conductors plus ground; 190 ft continuous, estimated; removed; two crushed sections disclosed; assembly weight basis unknown. The record reports visible facts without turning the exterior or a loaded-reel weight into a statement about internal conductor condition.
The specific error to avoid is calling a clean armor exterior proof of the internal conductors, or calling total assembly weight conductor weight. Keep the printed assembly, visible damage, history, length basis, and weight basis on the same line; leave any unsupported internal detail unknown.
- Fictional record fields: printed designation, internal-conductor markings, length basis, visible armor condition, service history, and assembly weight basis.
- Photograph accessible labels, armor, ends, and damaged areas without opening the cable assembly.