Let the printed designation lead
Use the full jacket legend as the primary identifier. Record TC, TC-ER, PLTC, or another designation only when it is actually visible on the cable or a matching record. Storage in a tray, a label written by hand, or a department name does not prove the product type. Photograph enough of the legend to keep the printed information tied to the reel ID.
The specific mistake is calling every cable associated with a tray “Type TC” and pooling its footage with all similar-looking reels. The resolution is to preserve the actual designation and keep unreadable reels on their own line. “Designation unknown” is a useful result when the evidence does not support a more precise label.
- Printed designation exactly as seen
- Manufacturer and part number if legible
- Marked voltage
- Reel ID used in both inventory and photo names
Split close specifications before totaling footage
Create separate rows for conductor count, pair count, gauge, shielding arrangement, jacket differences, and continuous footage. A twelve-conductor reel is not interchangeable with a fourteen-conductor reel simply because both are on wooden reels. Likewise, an overall shield and a per-pair shield must not be merged under one shorthand description.
The City of Fishers says its capital-project dashboard covers sanitary, transportation, trail and other infrastructure projects, with active project status available online. That dashboard is not evidence that a listed project contains control cable or that any cable is for sale; it only reinforces why a seller should move from a project label to a reel-specific record.
- Conductor count and pair count
- Gauge and shield arrangement
- Jacket construction
- Continuous footage with measured, documented, or estimated basis
Record ends, history, and supporting records
For each reel, photograph the label, accessible jacket, and accessible ends. State whether the cable is uninstalled or has been in service, whether fitted ends are present, and what visible jacket condition is known. These are inventory facts, not a statement that the cable is suitable for a particular use.
Attach a data sheet, packing list, or product record only when it can be matched to the same part number or reel reference. Where a document is not a clear match, retain the document as an unresolved discrepancy rather than using it to complete a field. The photograph and the record should point to the same line.
- End condition and fitted ends
- Service history or explicit unknown
- Visible jacket condition
- Document filename and matching part or reel reference
Illustrative specification line
Illustrative inventory example—not a purchased lot: CT-FI-03 is a fictional reel with a photographed TC-ER marking, twelve 16 AWG conductors, shielding unknown, 240 ft measured, and fitted ends noted. The example is intentionally incomplete: the unknown shield field stays visible rather than being inferred from the designation.
For an unreadable reel, use the same format with “designation unknown,” a distinct reel ID, footage basis, condition note, and photo references. That leaves a reviewer able to see exactly what is known before discussing the control or tray cable lot.
- Reel ID: CT-FI-03
- Designation: TC-ER marking photographed
- Construction: 12 conductors, 16 AWG; shielding unknown
- Quantity: 240 ft measured
- Condition: fitted ends noted