Document the complete feeder assembly
Start with the manufacturer designation, part number, and full readable jacket legend. Record the source of the conductor-metal identification and then list neutrals, shields, drain wires, and support members as separate construction fields. A silvery exposed surface does not establish that the complete assembly, or every component within it, is aluminum.
The New Bedford Economic Development Council lists commercial and industrial development opportunities, including infill sites with transportation access and conforming zoning, and describes a proposed 95-acre advanced manufacturing campus near I‑195 and Route‑140. This is limited local context for a seller with project or facility records; it does not prove that a particular feeder reel exists. The actual cable record must establish the construction, amount, and release status for the item being offered.
- Manufacturer and part number from the offered reel.
- Conductor-metal source from tag, jacket, or matching record.
- Neutral, shield, drain, and support details kept separate.
Use marked size and real remaining length
Record AWG or kcmil only when it appears on the jacket, tag, or a product record tied to the same designation. Outside diameter is not a dependable substitute for conductor size. List each continuous length and explain whether the footage is measured, documented, or estimated.
If a partial reel has an exposed end, photograph it as a condition detail without using the image to infer size or construction. A length estimate may still be useful when labeled honestly, but it should not be merged with a documented figure or treated as proof of the original reel quantity.
- Marked AWG or kcmil and its evidence source.
- Continuous footage for each reel or piece.
- Measured, documented, or estimated quantity basis.
Keep condition and mixed construction visible
Separate uninstalled reels, material taken from service, and uncertain items. Note jacket damage, flange wear, exposed ends, and known storage history as observations. Do not use a condition note to make an electrical-performance claim or to reclassify an otherwise uncertain assembly as a confirmed feeder.
When a neutral, shield, or support member cannot be confirmed, retain that uncertainty in the line. This is more useful than a simplified all-aluminum description because it lets the review focus on the evidence actually attached to the offered reel.
- Condition and service-history field.
- Jacket, flange, and end observations.
- Unknown construction elements identified plainly.
Add practical reel and release information
State storage location, reel dimensions, weight basis, known loading equipment, and release authority. Record a gross, net, or estimated weight as such; do not treat a reel tag or similar reel as a confirmed net figure. If the feeder is stored with other products, make the line reference visible in the location note.
These facts keep an item record useful without assuming freight, timing, or acceptance terms. A seller can send the line-item list and matching photos to saleselectricalbuyers@gmail.com for a lot-specific review after the form inquiry.
- Storage location and reel dimensions.
- Gross, net, or estimated weight basis.
- Loading information and release authority.
Illustrative feeder record with unknowns
The example below is fictional and is not a purchased lot. It demonstrates how a feeder can be described by a tag-supported designation while retaining an estimated length and unknown weight basis. The example should not be copied as a substitute for the markings on a real reel.
The mistake to avoid is treating visual metal appearance as proof of every conductor and then estimating AWG or kcmil from cable diameter. The practical correction is to preserve tag evidence, record marked size, and carry unresolved component details as unknown.
- Reference: NB-AL-03.
- Product: aluminum feeder designation from fictional reel tag; neutral construction documented.
- Quantity: 275 ft continuous, estimated.
- Condition: partial reel; exposed end noted; gross weight basis unknown.