1) Photograph the marked rating on the offered reel
Start with what is printed on the reel you are offering. Provide a photo that clearly shows the kV rating and the manufacturer part number as they appear on that reel. In your notes, transcribe the marked kV and the full part number exactly as printed, and include the manufacturer name, your internal or yard reel ID, and a photo reference so each image can be matched to the reel.
Avoid copying markings from nearby reels or cartons, even if they look identical. If the marking is partially obscured, submit the clearest available photo and state what portion is unreadable. Do not substitute values from project specs or submittals; capture what is actually present on the physical reel.
- Evidence to provide: marked kV, manufacturer, part number, reel ID, photo reference
2) Record only documented construction details
List insulation level, shield or neutral type, conductor metal, and size only when the offered reel or a matching document supports them. Examples of acceptable sources include the reel’s own tag/print, a label tied to that reel ID, or documentation that names the same part number and batch. Note the construction source you relied on so each field can be traced back.
If any construction element cannot be confirmed from the reel or a matching document, leave it explicitly unknown. Do not infer insulation level or shield design from a similar part used on the same project. Keeping unknowns explicit preserves traceability and prevents cross-contamination between reels.
- Evidence to provide: insulation, shield/neutral, conductor metal, size, construction source
3) Link production and test records by batch or reel
When you have production or test records, match them by reel or batch/lot ID and date. Note the record scope (for example, batch qualification or reel-specific test), the matching reel reference, and the record status. If no record matches the offered reel or batch, mark the record status as missing rather than borrowing a near match.
This step addresses the most common traceability failure: using a matching-looking reel to fill a missing rating or test history. Keep each document tied to the actual reel or batch it names, and do not treat documentation as a reuse certification. It is evidence for review, not a substitute for the item’s real, reel-specific history.
- Evidence to provide: batch/lot ID, record date, record scope, matching reel, record status
4) Describe storage, ends, and observable condition
Report the continuous length, end protection, any moisture exposure, visible damage, storage history, and reel dimensions for the offered reel. Note whether both ends are capped or otherwise protected, whether there is evidence of water ingress, and any handling marks on the reel flanges. Provide this as an objective description without making an electrical fitness claim.
If you cannot confirm the full continuous length or end condition, say so plainly and include what you do know (for example, a tag count or a note that one end cap is missing). Clear, reel-specific condition notes help keep the record accurate without implying a determination about future use.
- Evidence to provide: continuous length, end condition, moisture exposure, storage history, reel dimensions
5) What to do when information is incomplete
If markings are partially unreadable, document the readable portion, add a photo reference, and mark the remainder unknown. If construction details are not supported by a reel tag or a document that matches the same part number and batch, leave the field blank or unknown and cite the construction source you do have. If no batch or test record matches the offered reel or batch ID, set record status to missing.
Worcester’s investment material describes Gateway Park as a life-sciences and biotech destination and South Worcester Industrial Park as an 11-acre industrial site with remediation, demolition and infrastructure improvements. That project and industrial context does not establish any medium-voltage inventory. Its limited relevance is that a seller should tie project paperwork to the exact reel or batch it names, rather than treating a nearby development record as cable evidence.
Do not fill gaps with data from a neighboring or earlier project reel. The correct path is to keep unknown specifications explicit and maintain the link between any existing records and the exact reel or batch they identify. This preserves the traceability needed for evaluation.
6) Illustrative record format (example only)
Use the following illustrative format as a guide to organize your submission. This is not a purchased Worcester lot and does not imply a transaction. It demonstrates how to keep reel-specific facts and unknowns clear and separated from similar items.
Illustrative only — not a purchased Worcester lot: reference MV-WOR-06; identity: 15 kV marking photographed; quantity: 720 ft documented; records: no matching test record; one end cap missing. Notice how the kV marking is tied to a photo reference, the length is stated as documented, and missing records are marked missing rather than filled from a near match.
