Use an industrial-area reference as a locator only
The city lists seven industrial park areas: Tonquish Subdivisions 1 and 2, Westland Commerce Park, Westland Commerce Park South, Ford-Hix Industrial Park, Railway Industrial Park and Cherry Hill Industrial Park. A seller can use the actual listed area or another location to organize access information, but the public list does not identify an available armored-cable lot. The offered item still needs a cable-specific record tied to a reel, spool, or continuous length.
Start with a stable item ID and the complete designation shown on the product: for example, Type MC, MC-HL, TECK, or a manufacturer designation. Do not treat all metal-clad exteriors as interchangeable assemblies.
- Item ID and actual storage location
- Complete printed designation
- Manufacturer record where available
Describe the whole assembly
Record conductor count, size, stated metal, marked voltage, and any outer jacket information alongside the product designation. If a field is not readable from the accessible label or record, mark it unknown rather than assuming it from the armor pattern.
Keep fittings and terminations in separate fields. A connector, clamp, or end treatment can be relevant to the item record without proving its internal construction or condition.
- Conductor count, size, and stated metal
- Marked voltage and jacket
- Fittings or terminations
Photograph armor and visible damage without disassembly
Use photographs of accessible armor, ends, labels, and visible damage to document exterior condition. Note crushed sections, corrosion, missing fittings, and end condition by item ID. Visual condition should be described as visible evidence, not as proof of the condition inside the assembly.
If internal conductors or inaccessible ends cannot be verified, retain that limitation. The relevant seller action is accurate exterior documentation, not a claim about an unobserved internal state.
- Armor condition
- Crushed sections or corrosion
- End condition and accessible fittings
Separate length from every kind of weight
List continuous length for each item and label the quantity basis as measured, documented, or estimated. A weight also needs a basis: assembly weight, gross loaded-reel weight, or a separately documented cable figure. It must not be presented as conductor-only weight merely because the cable has armor.
The error to avoid is treating intact armor as proof of internal condition and loaded assembly weight as conductor weight. Correct the record by stating what was observed, what was weighed, and what remains unknown.
- Continuous length and quantity basis
- Weight value and weight basis
- Conductor weight status
Record history, release, and a fictional example
State whether the cable is uninstalled stock, removed material, or unknown history, followed by storage location, access limits, and release authority. An access or approval gap should remain visible rather than being implied away.
Illustrative example—not a purchased lot: AR-01 is a fictional Type MC item with three conductors plus ground, 190 estimated continuous feet, two disclosed crushed sections, removed history, and assembly weight basis unknown. It demonstrates fields for a seller record, not a representation of a purchased lot.