Read the product designation, not the storage location
Transcribe TC, TC-ER, PLTC, or the actual printed designation exactly as it appears, together with manufacturer, part number, and voltage marking when present. Cable found in a tray is not automatically Type TC. A storage or source description may be useful background, but it is not a product classification.
For each reel, record conductor count or pair count, gauge, shielding, jacket details, and the evidence source. Do not make a broad control-cable label conceal a different pair arrangement or shield. If the printing is unreadable, say unknown and connect the photograph to the same inventory reference.
- Exact product designation
- Manufacturer and part number
- Conductor or pair count and gauge
- Shielding, jacket, and voltage marking
Split small construction differences into separate lines
Create distinct inventory lines when count, gauge, shielding, jacket, designation, fitted ends, or continuous length differs. Reels may look alike while carrying different functions in their product records. Each line should preserve its own reel ID and footage basis rather than absorbing variation into a group total.
Record whether footage is measured, documented, or estimated. Photograph accessible ends and report fitted ends as part of the condition record. If a group is truly identical, name the matching evidence and preserve reel count, but leave an exception reel on its own line.
- Reel ID
- Continuous footage and quantity basis
- Fitted-end description
- Photo and data-sheet match
Resolve the tray-labeling error
The likely error is calling every cable removed from a tray Type TC and combining reels with different pair counts or shielding. The fix is to use actual markings and matching product records, keep one line per meaningful specification, and flag unknown designation or shield status explicitly.
Do not borrow a construction from a nearby cable or call a visual resemblance proof. A short unknown-field note is more commercially useful than an asserted classification that cannot be connected to the offered reel. Keep removed material history distinct if it is known.
- Unknown designation or shield field
- Service-history note when known
- Photo reference for marking
- Separate group for matching reels only
Lakeville context and a worked record
Lakeville identifies its 2026-2030 Capital Improvement Plan as a long-range framework for infrastructure needs, development objectives, projects and equipment acquisitions. This is limited context for organizing changed-scope records, not evidence that a city project produced control cable or that any material has a stated specification.
Illustrative fictional record—not a purchased lot: CT-LV-09; TC-ER marking; 12 conductors, 16 AWG; shield unknown; 240 ft continuous, measured; cable removed from service with fitted ends. The record keeps its unknown shield field separate from the confirmed marking and footage.
- Use actual jacket markings instead of tray location.
- Keep pair count and shielding differences visible.