What we need first — reel-verified markings
Start by photographing and transcribing every visible marking on the reel flange and cable tail: the marked kV rating, manufacturer name, and the precise part number. Record the reel ID or any stamped serial so the photo and transcription can be linked to that physical reel. Do not rely on a broad project tag or utility label when the reel itself carries a specific kV marking; the decision centers on reel-level traceability rather than project-level descriptions.
When any of those fields are missing from the reel or label, mark them explicitly as unknown in the submission and do not substitute a different reel’s marking or a project-wide assumption.
- Required: clear photo of marked kV on the reel
- Required: transcription of manufacturer and part number
- Required: visible reel ID or serial linked to the image
Document construction and cable components separately
Document conductor metal and size, insulation level, and any shield or neutral construction only when those details are visible on the reel or exist in a record explicitly matched to that reel. If the reel label lists only a family or trade name without construction specifics, state that the construction is unconfirmed and list what is unknown.
Always attach or reference a source document when you claim conductor size or shield configuration; indicate the document name and the reel ID it is claimed to match.
- List conductor metal and AWG/kcmil if shown
- State insulation dielectric level only if marked or documented
- Note shield/neutral type and whether it is visible or only asserted in a record
Match batch, production and test records by reel ID
When you provide production, batch or test records, explicitly link each record to the reel ID and record date. If a certificate or test report exists but is for a different batch or reel, mark it as a mismatch and do not treat it as evidence for this reel. If no matching record exists, state that plainly; do not imply that a project-level certificate covers this specific reel.
Record match status fields such as batch/lot ID, record date, record scope, and whether a confirmed match was found. This preserves transparency for reviewers assessing whether a reel’s rating and test history are verified.
- Attach records with the reel ID recorded on the record
- If a record is for another lot, label it: “mismatch — belongs to [batch/lot ID]”
- State explicitly when no matching record is found
Describe continuous footage, end condition and storage
List continuous footage documented on each reel rather than an aggregated project quantity. Photograph and describe end protection (end caps, taped tails), any missing end caps, and visible moisture or contamination. Provide known storage history such as indoor/outdoor, covered/uncovered, date range in storage, and any observed damage.
Also include physical reel dimensions and documented weight basis when available so reviewers can estimate the shipped quantity and handling needs.
- Continuous footage per reel (documented)
- End condition: presence/absence of end caps, damage to tail
- Storage history: indoor/outdoor, exposure notes, dates
- Dimensions and weight basis if documented
What to do with unknown or incomplete inventory
If a reel lacks a marked kV, matching part number, or a reel-specific batch record, leave those fields empty and state “unknown” rather than assigning values from a similar reel. Provide the best supporting photos and any records you have, but label unmatched documents clearly as non-matching. This honest provenance lets reviewers decide what additional inspection or tests are required.
If a test or certificate is available but the reel ID differs, include the record in your submission and label it as a mismatch so the reviewer knows it exists but is not proof of traceability for that reel.
- Do not substitute another reel’s marking for a missing kV
- Attach unmatched records with a clear mismatch label
- Provide photos showing the missing or ambiguous markings
Illustrative seller record (do not treat as a lot)
Use a concise reel record like the example below to show the level of detail to provide. This fictional illustrative record demonstrates leaving missing fields explicit and not using another reel’s record to fill gaps.
- Inventory ID: NLV-MV-01
- Rating: 15 kV marking photographed; insulation level unknown
- Quantity: 720 ft documented
- Condition: uninstalled reel; one missing end cap
- Records: no matching batch record located
Keep project context separate from the reel specification
North Las Vegas Public Works requires civil improvement plans for infrastructure, grading, commercial driveways and site improvements, and reviews dry-utility conduit and appurtenances in public rights-of-way. For a project seller, this is limited context for preserving a project reference and release record alongside actual reel evidence; it does not identify an offered cable lot.
- Record actual storage location and access limits
- Keep local context separate from reel identity and lot terms