Capture the construction that is actually marked
For each reel, transcribe the manufacturer designation, conductor metal, conductor size, marked voltage, and neutral or shield configuration from the tag, jacket, or matching record. Keep photos of every readable marking with the reel reference. The term underground project cable does not identify a single construction.
If the cable has several elements, record the complete configuration rather than only the largest conductor. When the tag does not supply a neutral or shield detail, mark that field unknown instead of assuming that similar reels have the same arrangement.
- Manufacturer designation
- Conductor metal and size
- Marked voltage
- Neutral or shield configuration
- Photo reference
Reconcile project records to each physical reel
Match the project or warehouse record to a physical reel ID. State the continuous footage on that reel and label the quantity as measured, documented, estimated, or unknown. Do not divide one project total among several reels unless the records and reel references support that allocation.
Keep partial balances visible. A total number may be useful background, but it cannot replace the individual lengths and specifications needed to understand the offered inventory.
- Reel ID
- Project or warehouse record reference
- Continuous footage and quantity basis
- Photo filename linked to the same reel
State the weight and condition basis separately
Record reel dimensions and every available weight with its basis: gross, net, estimated, or unknown. If a scale ticket or manufacturer record supplies a figure, identify that source. Gross loaded-reel weight should not be presented as cable or conductor weight.
Describe known end condition, storage exposure, packaging, and visible handling damage separately from product construction. If a condition detail is not known, leave it unknown rather than treating a reel overview photo as a complete record.
- Flange diameter, width, or other known dimensions
- Gross, net, estimated, or unknown weight
- End condition and storage exposure
- Visible damage and packaging notes
Use the PNM fact as documentation context, not lot proof
PNM says nearby North Albuquerque Acres substations were up to 34% above normal rating and average demand had grown more than 1% annually since 2017.
That public information makes an exact construction-and-reel documentation scenario locally relevant for distribution inventory; it does not identify any cable for sale, show buyer demand, or connect an actual seller to PNM. The offered reel’s own records remain the basis for a submission.
- Record actual storage location privately
- Identify release authority for the actual reels
- State seller-known access and loading constraints
Correct blanket project descriptions before submission
The common mistake is calling several reels underground project cable and assigning the project’s aggregate footage to all of them. Correct it by splitting the inventory by matching construction, preserving per-reel marked voltage and configuration, and retaining an explicit unknown where the supporting record is incomplete.
An illustrative fictional record is UD-08: one warehouse reel with a distribution designation from its tag, conductor and neutral configuration documented, 580 feet documented, and a gross weight that includes packaging; the loading limit is unknown. This is a fictional record, not a purchased lot. In a real record, keep the release authority and storage facts attached to that reel.
- Do not infer configuration from a project name
- Keep each reel’s balance and record reference together
- Retain unknown loading or condition fields