Why precise designation matters
Control and tray cables are commonly conflated in project lists because they look similar on a reel and were often installed together. Small differences — TC versus TC-ER marking, conductor count, shielding, pair arrangement, jacket compound, or fitted ends — change how a buyer, recycler, or specifier will treat a continuous length. Accurate designation avoids combining unlike items into a single footage total and preserves value and traceability.
This page focuses on splitting multi-conductor lines by variant based on the actual jacket legend and supporting records rather than the project, building, or tray where the cable was found.
- Differentiate by printed jacket legend (TC, TC-ER, PLTC, manufacturer part number).
- Separate inventory lines for unique conductor/pair counts, gauges, and shielding.
- Preserve each continuous measured length rather than summing disparate pieces.
Step 1 — Capture the full printed designation
Photograph every reel or cut end so the jacket legend is readable in at least one image. Transcribe the legend exactly into the inventory record, including any TC, TC-ER, PLTC indication, manufacturer name, and part number when present.
If the jacket includes voltage or other marked ratings, record them. If printed data contradicts project paperwork, keep both records and flag the conflict as instructed below.
- Required evidence fields: jacketLegend, productDesignation, manufacturer, partNumber, markedVoltage.
- Name photo files by the inventory reference so photos, datasheets, and labels are cross-referencable.
Step 2 — Split similar-looking variants
Even when reels came from the same project, create separate inventory lines when conductor count, pair count, gauge, shielding, jacket color/compound, or fitted-end configuration differ. Do not aggregate by project or tray location.
Use clear, short designations such as '12c-16AWG-shielded-TC-ER' in the record to show the differentiator that required the split.
- Required evidence fields: conductorCount, pairCount, gauge, shielding, jacket, fittedEnds.
- If shielding is unknown, mark shielding as unknown and include a photo showing the cut end if available.
Step 3 — Record the remaining piece
List each reel or cut length with a unique reelOrPieceId, measured continuous footage, and the quantity basis (single reel, each cut length). State condition: uninstalled surplus, removed cable, or another stated condition. Include serviceHistory where known (installed date, project, or 'unknown').
If you cannot measure continuous footage before listing, mark continuousFootage as estimated and provide how the estimate was derived; buyers will treat estimated lengths differently but can still assess the lot.
The City Engineering Division schedules, plans, designs, processes bids, administers and supervises public works and construction projects, and maintains infrastructure records and documents. That describes the City’s stated public-project recordkeeping role; it does not establish the designation, ownership, or availability of any control or tray cable.
- Required evidence fields: reelOrPieceId, continuousFootage, quantityBasis, condition, serviceHistory.
- When fitted ends are present, photograph and describe them in fittedEnds.
Step 4 — Attach matching evidence and flag conflicts
Attach photos and any manufacturer data sheets named by the same inventory reference. If jacket printing is unreadable or different sources contradict, record markingConflict and unknownFields explicitly rather than guessing.
Mark items with unreadable or unsupported types as 'unknown' for the designation and preserve the continuous length. This prevents accidental mislabeling and follows the resolution in the brief.
- Required evidence fields: photoReference, dataSheetReference, markingConflict, unknownFields.
- Do not combine items where markingConflict exists; keep them listed separately with the conflict noted.
Handling incomplete or unknown inventory
If a reel lacks readable jacket printing and no manufacturer paperwork is available, create an inventory line with the best-observed physical details (conductor count, gauge measured from listed records or markings, jacket color) and mark productDesignation as unknown. Attach clear photos and set markingConflict or unknownFields so reviewers know the limitation.
When project paperwork lists all tray removals as 'TC' but some reels show TC-ER or other markings, keep the photographed designation and the project note together on the record and flag the disagreement instead of overwriting the physical evidence.
- Honest flags: use markingConflict to preserve both records; use unknownFields when a required evidence element cannot be provided.
- Buyers will ask for resolution or inspection access; make that availability clear in the record.
Illustrative record (how to present one reel)
Provide a single, concise example line for each unique continuous length. The brief includes an illustrative record showing how to display the required fields and condition notes. Use that format as a template when documenting each reel or cut piece.
Keep the illustrative label clearly marked 'ILLUSTRATIVE ONLY — not a purchased lot' so readers know it is an example.
- Example: inventoryRef CT-FAY-02, designation 'TC-ER marking photographed; manufacturer part number unknown', construction '12 conductors, 16 AWG; shielding unknown', quantity '240 ft measured continuous', condition 'removed cable with fitted ends present'.