Read the jacket legend before naming the cable family
Cable found in a tray is not automatically Type TC. Start with the complete readable jacket legend and the reel tag, not the storage location. Transcribe Type TC, TC-ER, PLTC, or any other actual designation exactly, along with manufacturer, part number, and voltage marking. A description such as “control cable near an automation panel” is helpful background but cannot replace the product record.
The City of Greensboro reports more than $4.74 billion in capital investments and nearly 15,000 jobs announced in 2025, with major developments in aviation, manufacturing and technology. This is context for a possible commercial inventory situation, not proof that any local facility has cable for sale. The visible marking, not the industry name, controls the inventory line.
- Photograph overlapping portions of the entire readable jacket legend.
- Capture manufacturer, part number, designation, and voltage marking when present.
- Put a missing or unreadable legend on its own line marked as incomplete.
Split conductor, pair, and shield variations
Multi-conductor cable can share an outer color while differing in conductor count, pair count, gauge, and overall or individual shielding. Create a separate inventory line whenever one of those fields differs. Do not report one combined footage total for unlike construction, and do not assume a shield simply because another reel in the group has one.
This page addresses a specific recordkeeping error: collapsing look-alike partial reels into “control cable.” The workable correction is to list the exact construction variation first, then associate the length and end condition with that one variation. Unknown shielding can remain unknown; it should not be converted into a yes or no merely to complete the spreadsheet.
- Separate conductor count, pair count, conductor size, and shielding into distinct fields.
- State whether shielding is overall, individual, absent, or unknown only from visible evidence.
- Keep a different gauge or jacket designation on a different line even if reels are stored together.
Tie footage and fitted ends to the precise reel
Assign each reel or continuous piece a stable ID and use that same ID in its photos and any matching record. For a partial reel, record the remaining continuous footage and label it measured, documented, or estimated. A total of several short pieces is not the same as one continuous usable length, so retain the individual entries.
A clearly fictional example shows the expected level of precision: “Illustrative inventory example—not a purchased lot: CT-GSO-02; TC-ER; 12 conductors, 16 AWG; shielding unknown; 240 ft measured, partial reel; previously in service with fitted ends; history unknown.” It does not imply that this is a real local lot or that a particular construction will be accepted.
- Use a reel or piece ID in the inventory, photo filenames, and notes.
- Describe accessible fitted ends and visible jacket condition without modifying the cable.
- Keep measurement basis alongside every footage value.
State condition, history, and release separately from designation
After the specification is clear, state whether the cable is unused stock, project overrun, or previously in service. Add known storage exposure, visible damage, current location, and the person or role that can authorize release. A clean jacket does not prove history, and a project name does not fill an incomplete legend.
Submit the line-item record through the quote process and email supporting photos or a spreadsheet to saleselectricalbuyers@gmail.com. If a designation, history, or release contact is missing, identify it plainly. The submission supplies evidence for a review; it does not create a promise about acceptance, price, or movement of the cable.
- Keep unused, project-overrun, and prior-service categories visible.
- Record storage condition and visible damage as observations, not a test result.
- List release authority and location with each inventory line or site group.