Why separate control and tray cable lines matters
Multi-conductor cable that looks similar in a tray can differ in critical ways: designation (for example TC vs TC-ER), conductor count, pair count, AWG and shielding arrangement. Combining those items by storage location alone leads to misclassification and lost information. Our workflow is designed to preserve visible markings and discrete reel evidence so each continuous length can be evaluated on its own merits.
We require documentation tied to the physical item: photographed jacket designation, reel tags, and measured continuous footage. When unreadable markings exist, mark that designation unknown rather than merging incompatible reels.
The Raleigh Water CIP project list includes a D.E. Benton Water Treatment Plant 6MGD pump, E.M. Johnson treatment-plant electrical generator improvements, and 30- and 36-inch transmission-main projects. Those entries provide limited local treatment-plant context only; they do not identify the source of a seller’s cable, which still must be separated by its own printed designation and construction.
- Separate lines for each conductor/pair/gauge/shield combination
- Record jacket designation exactly as printed (TC, TC-ER, PLTC, etc.)
- Match photos and reel IDs to continuous footage and fitted ends
Step 1 — Transcribe the actual designation
Photograph and transcribe the full printed jacket designation on each reel or continuous length. Do not infer designation from the tray or previous labels. Record manufacturer, part number and any voltage marking that appears on the jacket.
If the jacket marking is partly readable, capture the best available photo, transcribe exactly what you see and note the unreadable portions. If no readable marking exists, mark the designation unknown and provide other evidence fields.
- Evidence to collect: jacket designation, manufacturer, part number, voltage marking
Step 2 — Keep conductor and pair variants apart
Create separate inventory lines for different conductor counts, pair counts, gauge (AWG) and shielding arrangements. For example, 12 conductors 16 AWG with overall foil is distinct from 12 conductors 16 AWG unshielded, and both are distinct from a 24-conductor construction.
When documenting, list conductor count, pair count if relevant, AWG and shield arrangement explicitly. If pair counts are implied by construction (e.g. twisted pairs within a multi-conductor), describe them in the pair count field rather than a generic conductor count.
- Evidence to collect: conductor count, pair count, AWG, shield arrangement, jacket
Step 3 — Preserve reel and end evidence
Match each reel’s tag, data sheet and photos to the continuous length you report. Report fitted ends and whether lengths are continuous, measured, documented or estimated. If reels are cut into multiple lengths, document each continuous length as a separate record with photo references.
Continuous footage should be measured or clearly estimated; indicate the basis (measured/documented/estimated) and include the photo reference and reel ID for traceability.
- Evidence to collect: reel ID, continuous footage, measured/documented/estimated, fitted ends, photo reference
Step 4 — Describe source and release
State whether the item is uninstalled stock, overrun or removed cable and provide storage location, access restrictions and the documented release authority. If ownership or release authorization is not yet documented, state that explicitly so we know the lot cannot be released until ownership is confirmed.
Provide context for condition status (for example removed cable with fitted ends) rather than assuming unused stock. Accurate source and release information speeds review and reduces the risk of misclassified lines.
- Evidence to collect: condition status, source context, storage location, access restrictions, release authority
Handling unreadable or incomplete inventory
When markings, reel tags or construction details are unreadable or missing, be explicit: mark designation unknown, record what evidence is missing and supply as many other fields as you can (for example conductor count, continuous footage and fitted ends).
Do not combine unreadable reels with clearly marked reels. Retain them as separate lines flagged for further inspection so each can be resolved or rejected based on documented evidence rather than assumption.
- Flag unreadable designation as unknown rather than applying a presumed type
- Keep shielding-unknown reels separate from confirmed shielded/unshielded lines
Illustrative fictional record
The following record is an example of how to complete the required fields for a single continuous length. It is illustrative and is not a purchased Raleigh lot.
Use this format for each separate line you submit so reviewers can compare jacket markings, reel ID, continuous footage and release authority without conflating distinct constructions.
- Inventory Ref: RA-CT-012
- Designation: TC-ER marking photographed
- Construction: 12 conductors, 16 AWG; shielding unknown
- Quantity: 240 ft continuous, measured
- Condition: removed cable; fitted ends present
- Release: owner authorization not yet documented