Capture the marked kV and full designation
Start with the offered reel, not a broad voltage label. Photograph and transcribe the marked kV, manufacturer, part number, and conductor size or metal when shown. The reel ID must be visible in the inventory so the product information can be connected to a particular continuous length.
A generic power-cable description or a look-alike reel does not fill an absent kV marking. Keep missing fields explicit and retain the close-up image that shows what is actually readable.
- Marked kV.
- Manufacturer and complete part number.
- Conductor size and metal when marked.
- Reel ID and close-up marking photo.
Record construction only from matching evidence
Insulation, insulation level, shield, and neutral details belong in separate fields. Use the reel printing or a product document that identifies the same reel or batch. A document for the same family but a different batch is an unmatched record, not an interchangeable specification.
This page addresses the traceability burden of voltage-rated material. Record a source-document reference alongside the reel ID so an unanswered construction field is clearly distinguished from a confirmed one.
- Insulation and insulation level.
- Shield and neutral construction.
- Source-document reference.
- A mismatch note for unlinked paperwork.
Match documents to the batch and reel
For each available production, inspection, or test record, compare reel ID, batch or lot ID, record date, and scope with the offered reel. A document that belongs to another batch must be retained as unrelated; it should not be used to supply a rating or history.
The key seller decision is whether the marked kV, construction records, and any batch documents trace to this specific reel and length. If they do not, state no matching record rather than assuming it does.
- Reel ID and batch or lot ID.
- Record date and scope.
- Explicit mismatch note.
- One continuous-footage entry per reel.
Describe ends and storage without a fitness claim
Record continuous footage with its documented, measured, or estimated basis. Note end protection, known moisture exposure, storage history, reel dimensions, and the basis for any weight. These are inventory observations, not an electrical-performance determination.
The common mistake is borrowing a certificate from a different batch. The resolution is to leave missing specifications visible, link only matching existing records, and disclose batch mismatches without altering the reel.
- Continuous footage and basis.
- End protection and moisture-exposure notes.
- Storage history.
- Dimensions and weight basis.
Use a bounded Bethlehem reference
The city identifies two downtowns with distinctive characters and links its economic-development work to tourism, entrepreneurship and development projects. The statement is only local project and commercial context; it does not identify a medium-voltage project, cable owner, or buyer requirement.
Illustrative inventory example—not a purchased lot: MV-BTH-05; 15 kV marking photographed; insulation level unknown; 720 ft documented; uninstalled reel with one missing end cap; no matching batch record. Email a record like this to saleselectricalbuyers@gmail.com or call +1 (614) 715-3047 to discuss the particular lot.