Capture the exact marking from the offered reel
Start with the reel actually being offered. Photograph and transcribe its reel ID, marked kV, manufacturer, full product designation or part number, and conductor metal and size where legible. Keep a partial marking partial: record the visible characters and identify the unreadable portion rather than completing it from a project specification or a neighboring reel.
A medium-voltage label is not enough by itself. Insulation level, shield or neutral construction, and cable-end condition may be separate fields. Keeping these observations on one reel reference prevents a broad voltage category from hiding a different construction.
- Use one reel ID in the inventory, photo filenames, and matching documents.
- Record the marked kV exactly as shown, along with manufacturer and product designation.
- Separate visible construction facts from unknown insulation, shield, or neutral details.
Link records only when their identity matches
Attach a data sheet, batch record, or existing report only when it names the same reel or a documented batch or lot that can be tied to that reel. Record the document date and scope so the reviewer can see what it covers. A report that merely describes a similar product is not a record for the offered cable.
The specific mistake this page prevents is filling a gap with a matching-looking reel or a record from another batch. The practical resolution is simple: retain the unmatched report as a separate reference if useful, mark the actual construction field unknown, and explain the mismatch in the inventory note.
- Record batch or lot ID only when the relationship to the reel is documented.
- List insulation level, shield or neutral detail, document date, and document scope separately.
- Flag records from another reel or batch as unmatched rather than treating them as support.
Describe condition and continuous length as observations
Record whether the reel is uninstalled, partly used, or removed, plus its continuous length and quantity basis. Note accessible end protection, known moisture exposure, visible jacket condition, and storage history. These facts help organize a purchasing review; they are not an electrical-performance statement or a condition certification.
The City says district energy has existed in Pittsburgh for more than 100 years and highlights district heating, solar PV, building upgrades and resilient infrastructure. That is limited context for careful facility and energy-project documentation, not evidence that a particular medium-voltage reel came from any of those activities.
- State whether footage is measured, documented, estimated, or unknown.
- Describe end protection and storage exposure factually, including missing information.
- Keep condition history separate from the marked kV and construction record.
Add handling facts without treating them as a move plan
For a large reel, record flange diameter, flange width, and whether the known weight is gross loaded-reel weight, cable-only weight, or unknown. Identify the loading resources and access limits the seller actually knows, along with the role that can authorize release. These are handling facts attached to the inventory, not a transport commitment.
If a measurement is not available, label it unknown or estimated and state the basis. Do not use one reel’s dimensions or a typical catalog value as an asserted measurement for another reel. A separate handling record is especially important when the item has specialized construction and incomplete documents.
- Record diameter and flange width per reel when known.
- Label weight gross, net, estimated, or unknown.
- Identify known loading resources, access limits, and release authority.
Worked fictional traceability record
This fictional example shows how a single reel can remain reviewable even when a batch report is missing. It is not a purchased lot, a representation of local inventory, or a statement that the cable is accepted. The unanswered insulation and report fields remain explicit.
For a real inventory, replace the sample values with the actual marking photograph, reel reference, length evidence, condition observation, and records that demonstrably match that reel. If no matching record is found, leave that result visible rather than borrowing a specification.
- Reference: MV-PGH-03
- Marking: 15 kV photographed; insulation level unknown.
- Quantity: 720 ft documented continuous.
- Condition: uninstalled reel; one end cap missing.
- Records: no matching batch report located.