Transcribe the complete feeder designation
Begin with the manufacturer designation or part number on the reel tag or a matching record. Record stated conductor metal, AWG or kcmil, and insulation wording exactly as provided. Outside diameter and exposed color can be useful photographs, but they do not establish the complete feeder construction.
Keep the evidence source with the line. If the tag is incomplete, list the readable designation and identify the missing metal, size, or insulation field as unknown rather than translating the reel into a more confident description.
- Manufacturer and part number.
- Stated metal evidence.
- AWG or kcmil and insulation wording.
- Source of the designation.
Record every assembly component that is known
A feeder assembly may include main conductors, a neutral, shield, support member, or another component. Record conductor count and the documented construction of each component where available. Do not describe the entire assembly only by its largest conductor or presume that every element shares the same metal.
Where a data sheet is used, make sure it matches the reel’s designation and retain its identifier in the line. If a neutral or support member is not documented, that component should remain unknown, not silently grouped into the aluminum statement.
- Conductor count.
- Neutral construction.
- Shield and support-member details.
- Configuration record reference.
Show remaining footage and physical reel condition
Give the reel ID, current continuous footage, and whether that figure is measured, documented, or estimated. Describe a partial reel, exposed end, flange issue, or visible jacket condition without treating visual information as proof of internal condition.
For an estimated length, say the method used and keep the estimate separate from documented footage. This preserves an honest quantity record and avoids guessing conductor size from reel dimensions.
- Reel ID.
- Continuous footage and quantity basis.
- End condition and reel condition.
- Method for an estimated length.
Keep local context narrow and useful
TNECD lists the Clarksville-Montgomery County Corporate Business Park South as a 75-acre M-2 Heavy Industrial site adjacent to four-lane access, with industrial-quality electric, natural gas, water and wastewater infrastructure. It is relevant only as industrial-site context for asking about actual storage and access details; it does not establish aluminum inventory, a customer connection, or a handling promise.
State the real storage condition, known access limits, and release authority for the offered reel. These submission fields complement the assembly record without suggesting that a location page determines the material’s specification or disposition.
- Storage condition.
- Access limit or unknown status.
- Release authority.
- Photo reference matched to reel ID.
Worked record: let unknown metal stay unknown
Illustrative inventory example—not a purchased lot: AL-CL-02 has an aluminum feeder designation from the reel tag, 4/0 AWG, with neutral construction documented. It contains 275 ft continuous, estimated, on a partial reel with an exposed end; gross weight basis is unknown. The example retains the known feeder facts and labels the unresolved quantity and weight fields.
A common mistake is treating silvery exposed metal as proof that every conductor is aluminum. The correction is to rely on matching product records, separate mixed or undocumented construction, and state unknowns clearly.
- Example reference: AL-CL-02.
- Neutral construction documented.
- Estimated footage and unknown weight basis stay visible.