Capture the exact marked rating
Photograph and transcribe the kV marking, manufacturer, complete part number, and reel ID for each offered reel. Do not replace a visible rating with a broad category label or infer a rating from the equipment associated with the original project. Each line should show the actual marking available on that item.
The City of Fort Worth’s economic-development vision is to compete nationally and internationally for creative, high-growth businesses, with goals including competitive edge, creative-business growth and community vitality. This is limited context for organizing infrastructure or production inventory; it does not establish an MV project, a customer, the cable condition, or a purchasing decision.
- Reel ID
- Marked kV rating
- Manufacturer and complete part number
- Readable tag and jacket-photo references
Record construction only where it is supported
Add conductor metal and size, insulation level, and shield or neutral details only from the reel or a matching product document. Keep the document reference with that reel. Similar diameter, color, or project use is not evidence that two reels share the same construction.
A common error is using a project specification or another matching-looking reel to complete a missing rating or shield detail. Instead, state the missing field as unknown and preserve the evidence that is available. This does not turn existing records into a safety or reuse approval.
- Conductor metal and size
- Insulation level when documented
- Shield or neutral details
- Construction-document reference
Trace every record to its reel or batch
If production, inspection, or test records already exist, record the batch or lot ID, date, scope, and whether the record actually matches the offered reel. A report without a matching reel or batch reference should be labeled unmatched. It can be retained as background but should not be used as support for a different reel.
This traceability step answers a buying-review question, not an electrical qualification question. Existing records may clarify what is documented, while their absence remains a material fact. Do not create a match by copying an adjacent reel’s file or by assigning a batch number that cannot be traced.
- Batch or lot ID
- Record date and scope
- Reel-to-record match status
- Missing or unmatched record noted
Show condition and handling limits
For each reel, record continuous footage, end protection, known moisture exposure, storage history, dimensions, and documented or estimated weight basis. Keep a missing end cap, unknown storage interval, or partial reel visible. A condition photo can document what it shows, but it should not be used to claim electrical performance.
An illustrative fictional inventory record: FW-MV-05; 15 kV marking photographed; insulation level unknown; 720 feet documented continuous; uninstalled reel with one missing end cap; storage history partly known; no matching test record located. That record is useful precisely because it does not borrow missing information from a project file.
- Continuous footage and basis
- End protection and visible condition
- Known storage or moisture exposure
- Dimensions and documented or estimated weight