Read the actual jacket designation first
A tray, control room, or machine area identifies where cable was found, not what the cable is. Photograph and transcribe the complete jacket legend, including TC, TC-ER, PLTC, or another printed designation when present. Add manufacturer, part number, and voltage marking only as the same reel or continuous piece supports them.
If only a partial legend is readable, preserve the exact readable text and label the rest unknown. Do not recast the item as Type TC because it was stored in a tray. The product record must come from the cable or a matching document, not the storage location.
- Copy the complete readable legend, not only the largest marking.
- Keep product designation and storage source in separate fields.
- Preserve partial markings as partial rather than assumed.
Split construction differences into separate lines
Create distinct lines whenever conductor count, pair count, gauge, shielding, or jacket construction differs. Similar-looking reels can have material differences that disappear in a pooled “control cable” entry. A 12-conductor 16 AWG reel and a 12-conductor 18 AWG reel remain separate, as do pieces with known and unknown shielding.
For a multi-pair item, record pair count only when supported by the printing or matching record. If shielding cannot be established, say so and keep the piece apart from a reel with documented shielding. The point is not to fill every field; it is to avoid making one item stand in for another.
- Split conductor count, pair count, gauge, shielding, and jacket differences.
- Keep unknown shielding separate from documented shielding.
- Do not make one reel the evidence for a similar-looking group.
Preserve continuity and fitted-end notes
List each reel and each continuous cut length with a reel ID or temporary reference, continuous footage, and quantity basis. Mark footage measured, documented, estimated, or unknown. Note fitted ends and visible damage as their own fields. Several cut pieces can add to a total, but they should not be represented as one continuous length.
If a connector obscures a legend or an end is inaccessible, state that limitation and provide the readable cable-body marking when available. There is no need to change the item to make it look cleaner. A transparent note preserves the information needed for a review.
- Use one reference for each reel or continuous cut.
- Label measured, documented, estimated, and unknown length distinctly.
- Describe fitted ends and visible damage without an approval claim.
Link photos and records to the same reference
Temple EDC says Temple has 2,000 acres of shovel-ready land and positions the city for manufacturing and distribution operations. That is broad manufacturing and distribution context, not proof of any Temple cable inventory. For an actual multi-conductor submission, the relevant work is local to the seller record: match the photo filename, data sheet, any existing inspection record, service-history note, and storage location to the same inventory reference.
A data sheet for a neighboring reel cannot fill a gap. If the document is missing, keep the jacket photo and partial identity record with that line, then mark the data-sheet match unknown. This lets the buyer see the limits of the evidence without combining unlike cable into a falsely complete record.
- Use the same reference in photo filenames and the inventory line.
- Identify whether a record matches the offered reel.
- Mark a missing data sheet as unknown, not as a match.
Undo the tray-wide footage error
The mistake is calling every cable removed from a tray Type TC and giving one total footage. Correct it by transcribing actual jacket markings, splitting conductor or pair and shielding differences, and keeping each continuous piece visible. This resolves the product-identity task rather than merely restating where the cable was stored.
A fictional record, CT-TEM-01, shows a TC-ER marking, 12 conductors, 16 AWG, unknown shielding, and 240 ft measured on one continuous piece with fitted ends. It is not a real Temple lot. It shows that one unknown field does not prevent the rest of an inventory line from being useful.
- Do not use tray location as a Type TC classification.
- Retain separate lines for unlike construction.
- Keep a continuous length separate from an aggregate total.