Make a designation log from the jacket
Photograph and transcribe the complete printed legend on each line. Record TC, TC-ER, PLTC, or any other readable designation exactly as shown, together with manufacturer, part number, and the photo filename. Being stored in a tray does not establish the designation, and an area label should not replace a jacket legend.
When text is obscured, make an unknown-designation line rather than assigning a type from nearby stock. A close-up of the unreadable area is still useful evidence because it identifies what remains to be resolved without turning a visual guess into a specification.
- Exact designation from jacket printing.
- Manufacturer and part number when visible.
- Photo filename and an unknown-designation note when needed.
Split count, gauge, and shielding variants
Create separate rows when conductor count, pair count, gauge, shielding, jacket, or fitted ends differ. Conductor count and pair count should each have their own field because they are not interchangeable descriptions. Keep a shield field even when the answer is unknown, and do not combine shielded and unshielded stock under one product label.
The typical mistake is classifying all cable found in a tray or near a control system as Type TC. The practical resolution is to rely on the actual designation, then preserve differences in count, gauge, shielding, jacket, and ends at the line level.
- Conductor count and pair count.
- Gauge and shielding.
- Jacket variation and fitted-end condition.
Preserve the quantity of each continuous piece
Give each reel or continuous piece a reference, photograph the reel condition, and state its remaining footage as measured, documented, or estimated. Two pieces with matching markings should remain separate if their continuous lengths or condition differ. If one reel holds an uncertain transition, identify the reference and describe the uncertainty instead of reporting a single unsupported length.
A seller does not need to resolve every unknown before beginning an inquiry. The useful first record tells a reviewer which quantity is solid, which is estimated, and which physical piece the photos describe.
- Reel reference and continuous footage.
- Measured, documented, or estimated quantity basis.
- Reel condition and photo reference.
Use local project references only as background
Lehi’s transportation page says the city has changed from a small farming community to an economic engine and discusses the Point of the Mountain Connector, 2100 North Freeway and Clubhouse Extension. That planning context may explain why an inventory file carries a project label, but it does not prove that a particular cable exists, belongs to the seller, or has a control or tray designation.
If a project document accompanies the record, use it only where it matches a part number or reel reference. The decisive evidence on this page remains the cable marking, construction fields, continuous footage, and the link between photographs and the physical piece.
- Do not infer product type from a project or storage location.
- Keep the project record separate from the jacket legend.
- Use matching part numbers to connect supporting documents.
Show a fictional variation record
Illustrative fictional record, not a purchased lot: reference CT-LH-03; TC-ER marking photographed; 12 conductors, 16 AWG; shielding unknown; 240 ft measured; removed cable with fitted ends present. The example shows that a seller can preserve an unknown shielding field without merging it into a known variant.
If pair count or jacket text cannot be read, leave it unknown and retain a photo of the marking. The correct next step is a clearer record, not a reconstructed designation from the tray location.
- Fictional reference: CT-LH-03.
- Known designation: TC-ER marking photographed.
- Known gap: shielding unknown.