Identify the whole armored assembly
Record the actual Type MC, MC-HL, TECK, or manufacturer designation when it is visible, along with manufacturer or part number, conductor metal, conductor count and size, marked voltage, jacket details, and grounding information. The metal exterior alone does not identify the internal assembly. A line should say what is supported by the tag or jacket and what remains unknown.
Photograph the readable label and relevant jacket areas, then connect those images to a reference in the inventory. Do not promote an exterior description into a claim about conductor size, metal, or electrical condition when the record does not establish it.
- Complete designation.
- Manufacturer or part number.
- Conductor metal and count or size when documented.
- Marked voltage and jacket or ground details.
- Photo references tied to the inventory reference.
Describe visible condition without changing the cable
Photograph accessible armor, outer jacket, cable ends, reel or spool, fitted terminations, and visible damage such as crushed sections or corrosion. Note whether the ends are protected or open and whether fittings remain attached. These observations document what is visible; they do not establish the condition of material that cannot be seen.
Keep the assembly intact while preparing the inquiry. A clear photographic record is more useful than altering the cable to expose a detail, and it preserves the stated continuous length and existing end condition.
- Armor and jacket condition.
- Fittings or terminations.
- Crushed sections and corrosion.
- End condition and photo references.
Separate history, length, and weight basis
State whether each line is unused stock, previously used cable, or recovery-only material. Record every continuous length, full or partial reel status, and whether length is measured, documented, or estimated. If a weight is supplied, label whether it applies to a loaded reel, the full assembly, or an unverified value; armor and jacket weight should not become an implied conductor total.
A previously used cable should not be described as new solely because it was not energized. Likewise, intact armor is not evidence of internal conductor condition. Keep observed exterior condition separate from any assessment that is not in the record.
- Known history category.
- Continuous length and full, partial, or cut status.
- Measured, documented, or estimated basis.
- Loaded-reel, assembly, or unknown weight basis.
Put authority and access on the same line
Identify ownership, release authority, exact storage site, access restrictions, and existing loading resources for the referenced cable. An item can be physically present but not available for a buying discussion until the release field is clear. Attaching those fields to the assembly reference avoids confusing a site contact with the authority to release material.
If approval is still pending, say so. Existing site information can guide a later conversation, but it does not set a collection method, payment arrangement, or timing.
- Ownership.
- Release authority.
- Storage location.
- Access restrictions.
- Existing loading resources.
Worked record and the intact-armor error
A fictional record could read “AR-SG-06; Type MC tag; three conductors plus ground; size on label; 190 ft continuous estimated; previously used; two crushed sections disclosed; conductor condition not established.” It is an illustrative inventory example, not a purchased lot. The wording makes the unresolved internal condition visible instead of hiding it behind the intact parts of the exterior.
The error is treating an intact armor surface as proof of conductor condition or calling prior-use material new. Correct it by recording the known history, visible damage, fitting details, quantity basis, and the limits of the available evidence separately.
- Example reference: AR-SG-06.
- Example length: 190 ft continuous, estimated.
- Example condition: two crushed sections disclosed.
- Example unknown: conductor condition not established.