Transcribe the reel construction exactly
Capture the manufacturer, part number, full designation, conductor material and size, marked voltage, and neutral or shield details from the tag, jacket, or matching document. A project nickname such as underground or distribution is useful background, but it does not identify one uniform product. Retain the technical fields separately so a reviewer can distinguish one reel from another.
If the tag omits a field, mark it unknown or pending. Do not borrow voltage, neutral, shield, or conductor details from a nearby reel because both were associated with the same job or storage area.
- Manufacturer and part number.
- Complete designation.
- Conductor material and size.
- Marked voltage.
- Neutral or shield details and stated unknowns.
Preserve quantity reel by reel
Give each reel its own ID and continuous-length field. State whether footage is measured, documented, or estimated, and keep a gross or net weight basis separate from length. Record reel dimensions when they are known, since a large reel may have handling constraints that a footage number alone cannot show.
If a reel has a partial tag or an incomplete count, retain that record and label the missing value. One reel’s documented footage should never become the quantity for another reel without a matching record.
- Reel ID.
- Continuous length.
- Measured, documented, or estimated basis.
- Gross or net weight basis.
- Reel dimensions when known.
Document ends, storage, and observed condition
Photograph accessible ends, visible jacket printing, the reel tag, and the overall reel. Record end condition, visible jacket condition, known storage history, and whether the cable is unused stock or previously used material. These are evidence fields, not electrical-performance claims, and they help preserve the differences between otherwise similar reels.
Use the reel ID in every image filename. If an end, label, or part of the jacket cannot be safely seen, say so rather than presenting a general photograph as complete documentation.
- End condition.
- Visible jacket condition.
- Known storage history.
- Unused-stock or prior-use status.
- Photo references matching the reel ID.
Record release and access independently
For each reel or group, state the storage location, authorized release contact, access limits, existing loading equipment, and any known handling restriction. These fields identify the real seller decision after the cable has been classified: whether the documented reel can be made available by the appropriate authority.
Do not treat a location page or a reel record as a transport arrangement. Where a release contact or access detail remains unknown, retain the uncertainty in the inventory so the cable specification is not confused with readiness to move.
- Storage location.
- Release authority.
- Access limits.
- Existing loading equipment.
- Known handling restriction.
Worked reel record and the project-label error
A fictional record can read “UD-SG-02; distribution designation from tag; neutral configuration pending; one reel; 580 ft documented; gross weight includes packaging; exact weight unknown.” It is an illustrative record, not a purchased lot. It separates the supported tag language from details still needing a matching record.
The error is using the phrase underground project cable as if it proves one voltage and one conductor configuration. The resolution is to split lines by their own product records and retain unknown voltage, neutral, shield, or length details rather than filling the gap from a neighboring reel.
- Example reference: UD-SG-02.
- Example quantity: 580 ft documented on one reel.
- Example unknown: neutral configuration and exact weight.
- Example weight basis: gross includes packaging.
