Start with the marking on the offered reel
Photograph and transcribe the marked kV, manufacturer, part number, reel ID, and visible product designation from the offered reel. Keep a photo reference beside the inventory line. A general label such as medium-voltage cable is not a substitute for the actual marking; it cannot identify the insulation, shield or neutral details, conductor information, or a particular rating.
When a marking is incomplete or hidden, state the missing field as unknown and explain the evidence available. Do not use the rating printed on a neighboring reel, a project schedule, or a similar product sheet to complete the line. The traceability record is most useful when every fact can be traced to the cable actually offered.
- Capture marked kV and product identifier from the offered reel.
- Use reel ID and photo reference on the same inventory line.
- Leave an unreadable rating or construction field unknown.
Link records to a reel or batch, not a look-alike
List any existing production, inspection, or other cable record by filename, date, stated scope, and batch or lot ID. Then note whether that identifier matches the offered reel or a documented batch relation. A record can provide valuable context when the link is clear; a record for a visually similar reel should remain separate rather than being presented as evidence for this line.
If the batch ID is absent from the reel or does not match the file, mark the match status as no match or unknown. Preserve the file in the record if it explains the discrepancy, but do not borrow its kV, construction, or history. This correction is more useful than a complete-looking file with an unsupported connection.
- Record filename, date, scope, batch or lot ID, and match status.
- Keep mismatched records visibly separate from the offered reel.
- Do not copy a rating from a similar reel.
Record handling facts without a performance conclusion
For each reel, record continuous footage, end condition, known storage history, visible moisture exposure, reel dimensions, and weight basis. State whether footage is measured, documented, estimated, or unknown. These facts help describe the inventory and its practical handling without making a statement about present electrical performance.
Keep uninstalled stock separate from cable that was previously in service. Photograph accessible ends, the reel, and readable jacket sections. If end protection, storage history, or moisture exposure is not known, say so. Honest uncertainty is better than treating a photograph or a general project description as a complete condition record.
- Record continuous footage and its evidence basis.
- Describe accessible ends and storage facts without a performance claim.
- Keep unknown moisture or history fields explicit.
A project name is context, not a cable rating
South Burlington’s Projects & Initiatives page lists the Bartlett Bay wastewater treatment facility upgrade, City Center/TIF work, stormwater projects, paving and other initiatives.
That city source can help identify a local project context for an inventory record, but it does not show that a project used medium-voltage cable or that a particular reel belongs to it. If a project name appears in a file, the seller still needs the reel’s marked kV, product identity, quantity, and matched record status. The source is useful background, not technical evidence for a reel.
- Match project documents to the specific reel or batch when possible.
- Do not use a project name in place of marked kV.
- Keep local context separate from product and record evidence.
Worked medium-voltage record
Illustrative example only—not a purchased South Burlington lot: MV-SB-09 has a photographed 15 kV marking and 720 ft documented continuous. Its reel ID and batch ID are recorded, but no matching record has been located for the batch. Insulation level, shield details, and storage history remain unknown in the inventory line.
The mistake would be attaching a document from a similar reel and describing it as MV-SB-09 evidence. The correction is to retain the photographed marking, the known quantity, the batch ID, and a no-match record status. The unknown fields remain visible until a document can be connected to the offered reel or its batch.
- Reference: MV-SB-09.
- Marking: 15 kV photographed; insulation level unknown.
- Quantity: 720 ft documented continuous.
- Records: batch ID recorded; matching record not located.