Start with the printed cable identity
A cable found in a tray is not automatically a particular product type. Transcribe the entire readable jacket legend and the manufacturer part number or tag reference. If a line is marked TC, TC-ER or another designation, record the wording exactly instead of extending the designation to neighboring material.
Put the printed designation, manufacturer, part number and marked voltage on the same inventory line. A missing or damaged legend should be identified as unknown. A location, project nickname or visual resemblance is not a substitute for a readable marking or matching record.
- Photograph the tag and a legible stretch of jacket printing.
- Record printed designation and marked voltage exactly as available.
- Mark unreadable characters or missing fields as unknown.
Split similar cable before grouping it
The seller decision is whether two visually similar lines really share the same control or tray construction. Separate conductor count, pair count, gauge, shielding and jacket differences into distinct rows. A 12-conductor unshielded line is not documented as the same item as a 12-conductor line with an overall shield.
Retain the reel or cut reference and continuous footage with the construction details. Do not merge partial reels simply because their outside jackets have a similar color. If the shielding status cannot be confirmed, keep that line separate from confirmed shielded and unshielded cable.
- Use separate fields for conductor count, pair count, gauge, shielding and jacket.
- Keep partial reels and cut lengths tied to a stable reference.
- Do not infer a designation from tray location.
Preserve length, ends and matched records
For each reel or cut length, state the remaining continuous footage and whether it is measured, documented or estimated. Note fitted ends and visible jacket damage as conditions, not as an electrical assessment. A short note about storage or removal history can explain why a record is incomplete.
Attach only documents that match the exact reference or manufacturer part number. A data sheet for a similar cable does not complete a missing line. Where no matching document exists, retain the visible wording and list the rest as unknown.
- Include reel ID, continuous footage, quantity basis and condition.
- Match every document name to the inventory reference it supports.
- Separate unknown construction from fully documented construction.
Correct the tray-location mistake
The common mistake is calling every cable removed from a tray Type TC, then combining different pair counts and shields. Correct it by returning to the actual jacket legend, splitting the inventory by construction and preserving unknown designation where no evidence supports a category.
Illustrative inventory example—not a purchased lot: CT-RIC-03 has a TC-ER marking, 12 conductors at 16 AWG, 240 feet measured continuous and fitted ends present. Shielding is unknown, so that field remains unknown and the record is not grouped with a confirmed shielded line.
- Use the actual marking before naming a cable family.
- Keep unknown shielding visible rather than assuming it.
- Describe visible ends without claiming suitability.
Richmond context for project references
The city's project page names Biotech Phase III–Leigh Street Streetscape and Arthur Ashe Boulevard Bridge Replacement among capital and transportation projects.
Those named projects are city context, not evidence that a particular cable lot exists or that the city is involved with a seller. If a seller has an actual closeout reference, it can accompany the cable record; the jacket marking and line-specific evidence still control the grouping decision.
- Use an actual project reference only as supporting context.
- Do not let project context replace construction evidence.