Use the printed designation as the starting point
Transcribe the designation exactly as shown, whether it is TC, TC-ER, PLTC, or another readable marking. Add the manufacturer, part number, marked voltage, and jacket text when available. A cable’s storage location or former route does not establish its product designation, and a generic “control wire” label cannot replace the full record.
If the printing is unreadable or a part number cannot be located, keep the line in the inventory with that limitation stated. A clear photograph of the available jacket text is more useful than a guessed classification.
- Record designation and jacket text exactly.
- Add manufacturer and part number where readable.
- Mark missing designation fields as unknown.
Split specification differences before grouping reels
Create separate rows when conductor count, pair count, gauge, shielding, or jacket differs. Reels can look alike on a shelf yet represent different assemblies. A group label may help organize them, but the individual line must retain the fields that show why it belongs in that group.
This is the core seller task for control and tray cable: decide which lines are genuinely the same specification and which are not. Do not combine footage merely because cable was stored together or came from the same facility.
- Use distinct fields for conductor count and pair count.
- Record gauge, shielding, and jacket separately.
- Group only after the printed and documented details match.
Record each available continuous piece
For every reel or piece, list its reference, continuous length, quantity basis, fitted ends, and visible jacket condition. Measured, documented, estimated, and unknown quantities should remain distinct. A removed piece with fitted ends is not the same inventory record as an uninstalled reel even when the product marking is similar.
Match a reel-label photo, jacket photo, and any data sheet to that same reference. If a supporting document cannot be matched exactly, state the uncertainty instead of assigning it to the most similar-looking cable.
- Keep fitted ends and condition on the item line.
- State the basis for each footage figure.
- Match photos and documents to the exact reference.
Keep city context limited to its evidence
The FHWA project profile describes a 7.8-mile extension from Angle Lake to the Federal Way Transit Center with three stations, parking, bike storage and passenger facilities. That is local infrastructure context only; it does not establish that a seller’s multi-conductor cable came from the project or has any particular designation.
The relevant seller record remains the cable itself: its printed designation, conductor or pair count, shielding, length, condition, location, and release authority. Add access information for the actual storage site without implying any movement arrangement.
- Do not infer cable type from a project or storage route.
- Record actual storage and access facts separately.
- Keep release authority visible for the offered lines.
Worked format for a cable with an unresolved field
Illustrative only — not a purchased lot: reference FW-CT-05; TC-ER marking, 12 conductors, 16 AWG; shielding unknown; 240 feet continuous, measured; previously used cable with fitted ends and incomplete history. The unknown shielding field should remain visible even though other designation details are documented.
The correction to the common mistake is to use the actual printed designation and separate meaningful conductor, pair, and shielding variants. Preserve each continuous length rather than rolling unlike lines into one total.
- Reference: FW-CT-05.
- Quantity basis: measured.
- Unknown: shielding; history incomplete.